2017
DOI: 10.1016/j.conbuildmat.2016.12.070
|View full text |Cite
|
Sign up to set email alerts
|

Durability performance evaluation of concrete containing TDFA (Tire Derived Fuel Ash)

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
5
0
2

Year Published

2017
2017
2022
2022

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 8 publications
(7 citation statements)
references
References 18 publications
0
5
0
2
Order By: Relevance
“…These safety and environmental concerns have provided continuous motivation to the research community to investigate the utilisation of TDFA in the construction industry, where it is used as a substitute for conventional fillers in asphalt concrete [ 141 ]. The chemical composition of TDFA is given in Table 6 [ 142 ]. TDFA contains 27.5–31.1% SiO 2 , Al 2 O 3 , and CaO, and these oxides are suitable for pozzolanic materials.…”
Section: Supplementary Cementitious Materials (Scms)mentioning
confidence: 99%
See 2 more Smart Citations
“…These safety and environmental concerns have provided continuous motivation to the research community to investigate the utilisation of TDFA in the construction industry, where it is used as a substitute for conventional fillers in asphalt concrete [ 141 ]. The chemical composition of TDFA is given in Table 6 [ 142 ]. TDFA contains 27.5–31.1% SiO 2 , Al 2 O 3 , and CaO, and these oxides are suitable for pozzolanic materials.…”
Section: Supplementary Cementitious Materials (Scms)mentioning
confidence: 99%
“…Because TDFA can absorb more water, and reduces workability, proper compaction is required for the preparation of mortar. Hyeok-Jung et al used water reducing agents to increase the workability of concrete [ 142 ]. Al-Akhras and Smadi have reported that the air content of TDFA concrete is reduced with increasing percentage of TDFA [ 143 ].…”
Section: Supplementary Cementitious Materials (Scms)mentioning
confidence: 99%
See 1 more Smart Citation
“…değerlendirilmesine olanak sağlamaktadır. UTH testleri 40x40x160 mm boyutlarında, 3 [8] tarafından yapılan çalışmada, %100 normal portland çimentosu ve %100 vollastonit içeren iki ayrı karışımın normal kıvamı için gereken suyun sırasıyla %32 ve %65 olduğunu belirlemişlerdir. Ayrıca, kullanılan vollastonit yüzdesi arttıkça süper akışkanlaştırıcının miktarının da arttığını tespit etmişlerdir.…”
Section: Ultrasonik Titreşim Hızı Deneyi (Uth)unclassified
“…Bununla birlikte, nüfus artışı, yaşam standartlarının yükselmesi, yapı teknolojisindeki ve kentsel dönüşüm projelerindeki ilerlemelerden dolayı geleneksel beton bazı durumlarda istenilen dayanım ve durabilite özelliklerini gösterememektedir. Artan talebin karşılanması ve istenilen beton özelliklerinin elde edilebilmesi için yapı sektöründeki araştırmacılar farklı beton türlerini tasarlamaya yönelmişlerdir [1][2][3][4][5]. Yüksek Performanslı Beton (YPB), bu farklı beton türlerinin en önemlilerinden birisi olarak dikkat çekmektedir.…”
Section: Introductionunclassified