2007
DOI: 10.1049/iet-gtd:20050194
|View full text |Cite
|
Sign up to set email alerts
|

Dynamic features of DC flashover on polluted insulators

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
5
0

Year Published

2011
2011
2022
2022

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 9 publications
(5 citation statements)
references
References 4 publications
0
5
0
Order By: Relevance
“…However, extensive experimental research shows that the critical current varies from 200 to 450 mA, up to 1 A, which is dependent on the pollution layer resistance and insulator profile. Many researchers developed the ionization or breakdown explanation with current over 200 mA for DC and AC [13][14][15]. In References [15][16][17], it was proposed a discharge mechanism close to the leader breakdown, where the ionization process of the arc stem plays an important role for the discharge guiding for low and high current (<1 A).…”
Section: The Mechanical Model Of Local Arc On Polluted Insulators Sur...mentioning
confidence: 99%
See 1 more Smart Citation
“…However, extensive experimental research shows that the critical current varies from 200 to 450 mA, up to 1 A, which is dependent on the pollution layer resistance and insulator profile. Many researchers developed the ionization or breakdown explanation with current over 200 mA for DC and AC [13][14][15]. In References [15][16][17], it was proposed a discharge mechanism close to the leader breakdown, where the ionization process of the arc stem plays an important role for the discharge guiding for low and high current (<1 A).…”
Section: The Mechanical Model Of Local Arc On Polluted Insulators Sur...mentioning
confidence: 99%
“…This ionization is thought to extend the arc to flashover. The ionization or breakdown explanation with current over 200 mA for DC and AC is developed [13][14][15]. In [15][16][17], a discharge mechanism close to the leader breakdown is proposed, where the ionization process of stem plays an important role in the discharge guiding for low and high current (<1 A).…”
Section: Introductionmentioning
confidence: 99%
“…At this instant, the initial discharge between HV rod electrode and the centre of the vat (Fig. 4) is considered to have a tubular form of uniform diameter [31], unlike its elongated form where it has an extended foot with its forefoot propagating during discharge elongation [23].…”
Section: Simulation Studymentioning
confidence: 99%
“…Unfortunately, the proposed criteria and mechanisms are not yet confirmed, and the disagreement between the various hypotheses remains a subject for discussion [22, 23].…”
Section: Introductionmentioning
confidence: 99%
“…leakage current, arc temperature, elongation, arc resistance and pollution resistance) are mostly been covered by dynamic models proposed to better explain/clarify the arc propagation process. Thus, much works have been reported in the literature to describe the flashover dynamic that happen in polluted insulators, in which each author propose/design its proper model to describe this phenomenon [1, 10,15,28]. Rizk and Nguyen [9] were among the first researchers in this area that propose modelling the DC flashover dynamic.…”
Section: Introductionmentioning
confidence: 99%