2011
DOI: 10.1016/j.fusengdes.2011.01.016
|View full text |Cite
|
Sign up to set email alerts
|

Dynamic response analysis of superconducting coils in Wendelstein 7-X and mechanical quench test

Abstract: The Wendelstein 7-X (W7-X) modular stellarator is under construction at the Max-PlanckInstitut für Plasmaphysik in Greifswald, Germany. The W7 X magnet system contains 70 superconducting (sc) coils which are supported by a massive central steel ring structure via bolted connections and by numerous welded as well as gliding inter-coil elements. Load tests on prototypes of bolted coil to support ring connections whose flanges partially open during high field operation, and of sliding support structures between t… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
8
0

Year Published

2011
2011
2021
2021

Publication Types

Select...
7

Relationship

3
4

Authors

Journals

citations
Cited by 8 publications
(10 citation statements)
references
References 14 publications
2
8
0
Order By: Relevance
“…Worth to mention test programs supported by intensive structural analysis for highly loaded NSEs, CSEs, cryolegs, and conductor connections [23], as well as for the mechanical quench test on the superconducting NPC type 2 under current [24], [25]. Quality assurance for incoming material is also very important.…”
Section: Benchmarking With Component Tests and During Assemblymentioning
confidence: 99%
“…Worth to mention test programs supported by intensive structural analysis for highly loaded NSEs, CSEs, cryolegs, and conductor connections [23], as well as for the mechanical quench test on the superconducting NPC type 2 under current [24], [25]. Quality assurance for incoming material is also very important.…”
Section: Benchmarking With Component Tests and During Assemblymentioning
confidence: 99%
“…Worth to mention are particularly test programs supported by intensive structural analysis for highly loaded NSEs [13,14], CSEs [15], cryolegs [16] and conductor connections [17], as well as for the mechanical quench test on the superconducting NPC type 2 under current [27,28].…”
Section: 3mentioning
confidence: 99%
“…For higher efficiency, ten wires were placed in one groove by the 2 × 5 arrangement with series connection. e operating current is 400 A. e stability of superconducting magnet mechanical structure is one of the main reasons for quench [5][6][7][8], so the stress-strain analysis on the magnet structure plays an important role on the magnet design [9][10][11][12][13][14][15], particularly for the complex structure of the CCT quadrupole magnet. e analysis model is created by cutting a section from the structure with a pitch owing to its periodic symmetry in the axial direction.…”
Section: Introductionmentioning
confidence: 99%