ECG PQRST complex detector and heart rate variability analysis using temporal characteristics of fiducial points

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
14
0
1

Year Published

2022
2022
2024
2024

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 22 publications
(16 citation statements)
references
References 45 publications
1
14
0
1
Order By: Relevance
“…The characteristic P, Q, R, S, and T peaks are almost identical to these two types of electrodes, with the P wave, QRS complex, and T wave corresponding to the activation of the atria, activation and depolarization of the ventricles, and repolarization of the ventricles, respectively. [ 73 ] Although the bGaIn‐HRHP electrodes (3.5 cm 2 ) have a much smaller contact area than the Ag/AgCl electrodes (21.2 cm 2 ), the signal‐to‐noise ratio (SNR) defined as SNR false(dBfalse)=20logVrmslVrmsn${\rm{SNR}}\ ({\rm{dB}}) = 20{\rm{log}}\frac{{{V_{{\rm{rmsl}}}}}}{{{V_{{\rm{rmsn}}}}}}$ (with V rmsl and V rmsn representing the root mean square value of the ECG signals without and with noise) [ 74 ] of 45.27 dB is still higher than that of Ag/AgCl electrodes (30.82 dB).…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…The characteristic P, Q, R, S, and T peaks are almost identical to these two types of electrodes, with the P wave, QRS complex, and T wave corresponding to the activation of the atria, activation and depolarization of the ventricles, and repolarization of the ventricles, respectively. [ 73 ] Although the bGaIn‐HRHP electrodes (3.5 cm 2 ) have a much smaller contact area than the Ag/AgCl electrodes (21.2 cm 2 ), the signal‐to‐noise ratio (SNR) defined as SNR false(dBfalse)=20logVrmslVrmsn${\rm{SNR}}\ ({\rm{dB}}) = 20{\rm{log}}\frac{{{V_{{\rm{rmsl}}}}}}{{{V_{{\rm{rmsn}}}}}}$ (with V rmsl and V rmsn representing the root mean square value of the ECG signals without and with noise) [ 74 ] of 45.27 dB is still higher than that of Ag/AgCl electrodes (30.82 dB).…”
Section: Resultsmentioning
confidence: 99%
“…The characteristic P, Q, R, S, and T peaks are almost identical to these two types of electrodes, with the P wave, QRS complex, and T wave corresponding to the activation of the atria, activation and depolarization of the ventricles, and repolarization of the ventricles, respectively. [73] Although the bGaIn-HRHP electrodes (3.5 cm 2 ) have a much smaller contact area than the Ag/AgCl electrodes (21.2 cm 2 ), the signal-to-noise ratio (SNR) defined as…”
Section: Multifunctional Sensing System For Human Health Monitoringmentioning
confidence: 99%
“…The sensitivity of this approach to HF noise and subjective selection of the PVC starting time instant can be explored in future work. Next, the use of automatic detection of depolarization beginning such as [25] can be examined in the future to speed up and automate the signal processing procedure.…”
Section: Discussionmentioning
confidence: 99%
“…Figure 11 shows the HRV results at the time of hypotension in five hemodialysis patients using the HRV analysis method introduced in [ 43 , 44 ]. Among the HRV parameters, HR per minute (beats per minute (BPM)), RR interval trend, RR histogram, power spectrum, and Poincaré plot were used.…”
Section: Discussionmentioning
confidence: 99%