2011
DOI: 10.1161/circresaha.110.239574
|View full text |Cite
|
Sign up to set email alerts
|

Echocardiographic Speckle-Tracking Based Strain Imaging for Rapid Cardiovascular Phenotyping in Mice

Abstract: Rationale High-sensitivity in vivo phenotyping of cardiac function is essential for evaluating genes of interest and novel therapies in small animal models of cardiovascular disease. Transthoracic echocardiography is the principal method currently used for assessing cardiac structure and function; however, standard echocardiographic techniques are relatively insensitive to early or subtle changes in cardiac performance, particularly in mice. Objective To develop and validate an echocardiographic strain imagi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

17
257
0
1

Year Published

2013
2013
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 216 publications
(275 citation statements)
references
References 42 publications
17
257
0
1
Order By: Relevance
“…Baseline strain and strain rate values were in good agreement with previously published values using the same scanner model and analysis software 23. Global analyses revealed E || reductions from baseline to day 2 post‐MI of −17.8±0.5 to −11.8±0.6 in controls and −18.6±0.7 to −11.6±1.1 in the ivabradine group (34% and 37% reductions in the control and ivabradine groups, respectively; Figure 5A).…”
Section: Resultssupporting
confidence: 86%
See 1 more Smart Citation
“…Baseline strain and strain rate values were in good agreement with previously published values using the same scanner model and analysis software 23. Global analyses revealed E || reductions from baseline to day 2 post‐MI of −17.8±0.5 to −11.8±0.6 in controls and −18.6±0.7 to −11.6±1.1 in the ivabradine group (34% and 37% reductions in the control and ivabradine groups, respectively; Figure 5A).…”
Section: Resultssupporting
confidence: 86%
“…Longitudinal strain was chosen for strain analysis because it has been shown to be more sensitive and reliable than circumferential and radial strain for measuring LV function and has been demonstrated to have strong clinical relevance 23, 24, 25…”
Section: Methodsmentioning
confidence: 99%
“…Although ETT and cardiac scan have acceptable sensitivity and specificity, high rate of false positive and false negative results as well as their time-consuming nature causes them not to be an appropriate choice in emergency set. STE is a new non-invasive imaging technique that permits assessment of global and regional myocardial function independently from both cardiac translational movements and beam angle in a short time (1)(2)(3)(4)(5). STE is accepted as a diagnostic method in ACS cases for evaluation of myocardial wall motion at rest and during stress (12).…”
Section: Discussionmentioning
confidence: 99%
“…Speckle Tracking Echocardiography (STE) is a new non-invasive imaging technique that permits assessment of global and regional myocardial function independently from both cardiac translational movements and beam angle (1)(2)(3)(4). It is based on analysis of spatial displacement of spots during cardiac cycle and can capture myocardial deformation in 3 dimensions: radial, circumferential, and longitudinal.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation