Purpose: This study was conducted to verify the effect of applying a pressure biofeedback unit on walking ability and knee joint function while performing knee joint extensor strengthening exercises using resistance exercise equipment in total knee replacement (TKR) patients. Methods: This study was conducted on twelve patients receiving rehabilitation treatment after being admitted to a rehabilitation hospital post-TKR. Of these, six were allocated to a feedback group with a pressure biofeedback unit, and the other 6 were allocated to a control group without a pressure biofeedback unit. The subjects performed an exercise program for 45 minutes per session, five times a week, for two weeks. Walking ability and knee joint function were evaluated and analyzed before and after exercise. Results: The feedback group showed significantly better improvements in walking speed, gait cycle, step length on the non-operation side, time on the foot on the operation side, K-WOMAC stiffness, and K-WOMAC function than the control group (p< 0.05).
Conclusion:When strengthening the knee joint extensor muscles using resistance exercise equipment in TKR patients, the provision of a pressure biofeedback unit was found to improve walking ability and knee joint function by inducing concentric-eccentric contraction of the knee joint extensor muscles. Therefore, the study shows that exercise based on the provision of a pressure biofeedback unit should be considered when strengthening knee joint extensor muscles to improve the walking ability and knee joint function of TKR patients in clinical practice.