Effect of cutting flute length and shape on insertion and removal torque of orthodontic mini-implants

Abstract: (Table 1).일정한 회전속도와 수직력을 갖는 구동 모터식 토크 시험기(Biomaterials Korea Inc., Seoul, Korea)를 이용하여 삽입 및 제거 시의 토크를 연속적으로 측 정하였다 (Fig 2). 연속적으로 측정된 데이터는 시간 에 따른 토크의 변화량으로 도시하여 삽입 시간 및 토크를 쉽게 알아볼 수 있도록 하였다. (Fig 4). 이후 나머지 모든 미니 임플랜트들도 제거되었으며 제거된 미니 임플 랜트들은 토크에 영향을 줄 수 있는 미니 임플랜트 tip이나 thread의 변형이 없는지 확인하기 위해 공구 현미경(MF-A1010H, Mitutoyo, Japan)을 이용하여 5 배율로 관찰하였다 (Fig 5). (Table 3). 피질골 두께가 2 mm에서 4 mm로 증가함에 따른 총 삽입 시간의 변 화는 A군에서 가장 큰 증가를 보였으며, C군에서 가장 작은 증가를 보였다 (Fig 6). 최대 삽입 토크(Maximum insertion torque)미니 임플랜트의 식립 과정 … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
4
0

Year Published

2011
2011
2021
2021

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(4 citation statements)
references
References 20 publications
0
4
0
Order By: Relevance
“…A total of 23 articles fulfilled the eligibility criteria (Table 1). 13,14,16,3958 Five of these articles were either complete or partial copies of original articles, and another three articles were suspect of duplicate publication because they appeared almost identical (Table 1). To control publication bias, multiple publications were counted as one study, and references of duplicate articles were only listed in the tables and not in the text of this article.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…A total of 23 articles fulfilled the eligibility criteria (Table 1). 13,14,16,3958 Five of these articles were either complete or partial copies of original articles, and another three articles were suspect of duplicate publication because they appeared almost identical (Table 1). To control publication bias, multiple publications were counted as one study, and references of duplicate articles were only listed in the tables and not in the text of this article.…”
Section: Resultsmentioning
confidence: 99%
“…41,42,48 Associations were presented for thread depth, pitch size, the presence of fluting, and the design of the fluting of the screw. 16,39,45 Variations in the surface treatment of OMIs also affected MIT levels. 50,52…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…This type of screws are characterized by sharp pitches and a penetrating screw apex and do not necessarily have osseointegration-promoting surface treatment. [1][2][3] The other type is a pilot-drilling self-tapping screw system. [4][5][6] This type requires the placement of a pilot hole at the recipient site before engaging the self-tapping screw.…”
Section: Introductionmentioning
confidence: 99%