Abstract: Current shortages of Filtering Facepiece Respirators (FFRs) have created a demand for effective methods for N95 decontamination and reuse. Before implementing any reuse strategy it is important to determine what effects the proposed method has on the physical functioning of the FFR. Here we investigate the effects of two potential methods for decontamination; dry heat at 95 °C, and autoclave treatments. We test both fit and filtration efficiency for each method. For the dry heat treatment we consider the 3M 18… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
10
0

Year Published

2020
2020
2021
2021

Publication Types

Select...
3
3

Relationship

1
5

Authors

Journals

citations
Cited by 7 publications
(10 citation statements)
references
References 7 publications
0
10
0
Order By: Relevance
“…Overall, 16 studies measured disinfection and durability 12, 15, 19, 20, 22, 27-30, 33, 36, 47, 49, 51, 62, 64 , 16 studies measured only disinfection 13, 18, 23, 24, 31, 38, 40, 41, 43, 44, 48, 56, 63, 65-67 and 26 studies measured only durability 7, 14, 16, 17, 21, 25, 26, 32, 34, 35, 37, 39, 42, 45, 46, 50, 52-55, 57-61, 68 . Thus, 32 studies measured disinfection and 42 measured durability.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…Overall, 16 studies measured disinfection and durability 12, 15, 19, 20, 22, 27-30, 33, 36, 47, 49, 51, 62, 64 , 16 studies measured only disinfection 13, 18, 23, 24, 31, 38, 40, 41, 43, 44, 48, 56, 63, 65-67 and 26 studies measured only durability 7, 14, 16, 17, 21, 25, 26, 32, 34, 35, 37, 39, 42, 45, 46, 50, 52-55, 57-61, 68 . Thus, 32 studies measured disinfection and 42 measured durability.…”
Section: Resultsmentioning
confidence: 99%
“…Autoclaving (n=14) 14, 30, 34, 42, 45, 55, 57, 59 and ethanol disinfection (n=14) 15-17, 29, 42, 45, 53, 58 led to failures within two disinfection cycles in 12 and 13 tests, respectively. This indicates these methods cannot be utilized for N95 reuse.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…For example the use of UV respirator treatment is limited by the availability of appropriate UV lamps and concern about their ability to deliver sterilization beyond the exposed respirator surface [3]. Autoclave treatment is broadly available but utility is limited to a subset of pleated (rather than molded) construction [3,12]. Vaporized or gaseous hydrogen peroxide methods require relatively expensive and complex devices that may be in limited supply in the current circumstance.…”
Section: Discussionmentioning
confidence: 99%
“…Heat remains a widely accessible strategy for decontamination of PPE due to the ubiquity of ovens that can achieve sufficient temperatures and the ease of translating and communicating effective protocols. Furthermore, the temperatures and treatment times used in this study do not negatively impact respirator integrity (2, 16, 38), which is essential for this method’s applicability. To support the use of effective N95 decontamination approaches during the COVID-19 pandemic, the USFDA provided a number of emergency use authorizations (EUAs) and published recommendations for evaluating N95 decontamination methods.…”
Section: Discussionmentioning
confidence: 99%