Effect of electrode size and spacing on electrograms: Optimized electrode configuration for near-field electrogram characterization

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

1
20
1

Year Published

2022
2022
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 20 publications
(22 citation statements)
references
References 13 publications
1
20
1
Order By: Relevance
“…Peak-to-peak voltage is used as a marker to distinguish healthy from pathological tissue both for biEGMs ( Jadidi et al, 2020 ) and uEGMs ( Nairn et al, 2020b ). However, biEGM amplitude can be affected by to several factors ( Hwang et al, 2019 ) such as the orientation of the catheter ( Schuler et al, 2013 ; Gaeta et al, 2020 ), the electrode spacing and size ( Beheshti et al, 2018 ; Abdi et al, 2020 ; Nairn et al, 2020a ; Takigawa et al, 2022 ), depolarization patterns ( Jacquemet et al, 2003 ), substrate remodeling ( Jacquemet et al, 2003 ; McDowell et al, 2012 ; Campos et al, 2013 ; Mendonca Costa et al, 2014 ; Roney et al, 2016 ; Sánchez et al, 2021b ) and signal filter settings ( Starreveld et al, 2020 ).…”
Section: Intracardiac Electrogramsmentioning
confidence: 99%
“…Peak-to-peak voltage is used as a marker to distinguish healthy from pathological tissue both for biEGMs ( Jadidi et al, 2020 ) and uEGMs ( Nairn et al, 2020b ). However, biEGM amplitude can be affected by to several factors ( Hwang et al, 2019 ) such as the orientation of the catheter ( Schuler et al, 2013 ; Gaeta et al, 2020 ), the electrode spacing and size ( Beheshti et al, 2018 ; Abdi et al, 2020 ; Nairn et al, 2020a ; Takigawa et al, 2022 ), depolarization patterns ( Jacquemet et al, 2003 ), substrate remodeling ( Jacquemet et al, 2003 ; McDowell et al, 2012 ; Campos et al, 2013 ; Mendonca Costa et al, 2014 ; Roney et al, 2016 ; Sánchez et al, 2021b ) and signal filter settings ( Starreveld et al, 2020 ).…”
Section: Intracardiac Electrogramsmentioning
confidence: 99%
“…Second, the catheter’s small electrode (0.9 mm 2 ) may improve OWM’s accuracy as it can reduce the recording of far-field potentials. 4 , 5 Third, this catheter has a reference electrode at the confluence of the splines (TRUEref technology; Biosense Webster, Inc). This reference electrode might increase the OWM’s quality by reducing the impact of the far-field potentials on unipolar signals.…”
Section: Discussionmentioning
confidence: 99%
“…Many aspects of the signal acquisition influence the morphology of the contact electrograms [10]. This in silico study focuses on characterising the influence on OE morphology of inter-electrode distance and the number of electrodes in the clique.…”
Section: Introductionmentioning