Effect of pollution severity on electric field distribution along a polymeric insulator

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
10
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
6
1

Relationship

2
5

Authors

Journals

citations
Cited by 28 publications
(11 citation statements)
references
References 11 publications
1
10
0
Order By: Relevance
“…Whereas, the electric field in contaminated condition is higher compare to the noncontaminated layer. Effect of pollution severity on electric field distribution was studied in [24], and it was shown that electric field intensity increases with increase in pollution severity. Besides that, it was found that the current density is also higher in contaminated condition compared to the non-contaminated condition as reported earlier by Arshad (2015) [25].…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Whereas, the electric field in contaminated condition is higher compare to the noncontaminated layer. Effect of pollution severity on electric field distribution was studied in [24], and it was shown that electric field intensity increases with increase in pollution severity. Besides that, it was found that the current density is also higher in contaminated condition compared to the non-contaminated condition as reported earlier by Arshad (2015) [25].…”
Section: Resultsmentioning
confidence: 99%
“…Effect of pollution severity on electric field distribution was studied in [24], and it was shown that electric field intensity increases with increase in pollution severity. Besides that, it was found that the current density is also higher in contaminated condition compared to the non-contaminated condition as reported earlier by Arshad (2015) [25]. When the electric conductivity of the contamination is higher, the current density is high and the electric field is low.…”
Section: Resultsmentioning
confidence: 99%
“…Electric field calculation along an outdoor insulator is considered to be one of the most reliable diagnostic tools. Experimental and numerical investigations have been carried out previously to locate defects in outdoor insulators using electric field calculations [28,29]. In this paper, various contamination and dry band conditions were considered to calculate the electric field distribution along the surface of the silicone rubber insulator.…”
Section: Electric Field Distributionmentioning
confidence: 99%
“…OSs varies from location to location. Depending upon the location of insulators, multiple factors may be acting together to cause insulators' deterioration, and these were the cause of 2nd and 3rd generation polymer insulators' failure [7][8][9][10]. Early insulators suffered from weather and degraded by UV radiations.…”
Section: Introductionmentioning
confidence: 99%