Effect of Process Parameters on Electrochemical Performance of a Glutamate Microbiosensor

Abstract: The effect of process parameters on the electrochemical performance of a glutamate (Glu) microbiosensor was studied. Glu is a major excitatory neurochemical that is essential for regulation of several brain functions. Glu dysregulation is associated with several neuropathological conditions such as epilepsy, Parkinson's and Alzheimer's disease. Here, an enzymatic microbiosensor in the form of a ceramic-shank substrate enabled platinum (Pt) microelectrode array (MEA) was employed to investigate the effect of ke… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
12
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
7

Relationship

3
4

Authors

Journals

citations
Cited by 10 publications
(15 citation statements)
references
References 51 publications
2
12
0
Order By: Relevance
“…The exposed Pt microwires were electrochemically cleaned using the cyclic voltammetry (CV) method. The CV was run in a 2-electrode setup using an Ag/AgCl reference/counter electrode in a 0.05 M H 2 SO 4 electrolyte solution, and the potential was cycled between − 0.3 V to + 1.0 V with a 20 mV/s scan rate for 15 cycles 76,78 . The rationale for cleaning the microwire is to increase hydrogen peroxide sensitivity, which is due to significant reductions in the charge transfer resistances of the Pt microelectrode grains and grain boundaries (details not shown).…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…The exposed Pt microwires were electrochemically cleaned using the cyclic voltammetry (CV) method. The CV was run in a 2-electrode setup using an Ag/AgCl reference/counter electrode in a 0.05 M H 2 SO 4 electrolyte solution, and the potential was cycled between − 0.3 V to + 1.0 V with a 20 mV/s scan rate for 15 cycles 76,78 . The rationale for cleaning the microwire is to increase hydrogen peroxide sensitivity, which is due to significant reductions in the charge transfer resistances of the Pt microelectrode grains and grain boundaries (details not shown).…”
Section: Methodsmentioning
confidence: 99%
“…The third microwire, called the sentinel channel, was constructed by applying only the enzyme matrix solution with BSA and glutaraldehyde (i.e., the matrix does not contain any enzymes). The sentinel microsensor plays an important role in measuring the presence of small electroactive molecules (interferents) present in the vicinity of the biosensor probe that can be easily oxidized at the + 0.7 V applied to all three Pt microwires 76 . Examples of common interferents are nitric oxide, dopamine and AA.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Each ceramic wafer contained 56 microelectrodes. Upon diamond cutting of the wafer into discrete probes, each new probe contained eight platinized, platinum microelectrodes (100 µM × 50 µM) in four pairs shown in Figure 2 [ 25 ].…”
Section: Methodsmentioning
confidence: 99%
“…The temporal resolution of CA makes it possible to study neurochemical events on millisecond timescales. The simple mechanism of CA grants it the ability to continuously record for several hours [ 41 , 42 ].…”
Section: Electrochemical Sensorsmentioning
confidence: 99%