2016
DOI: 10.1002/fuce.201600096
|View full text |Cite
|
Sign up to set email alerts
|

Effect of Serpentine Multi‐pass Flow Field Channel Orientation in the Liquid Water Distributions and Cell Performance

Abstract: A commercial 50 cm2 polymer electrolyte membrane (PEM) fuel cell with serpentine flow fields was operated at 2.0 bar and 60 °C with two orientations of the flow field channels with respect to gravity, i.e. horizontal and vertical channels. A 3 × 3 test matrix of anode and cathode reactants relative humidity was used for the performance assessment of the cell in both orientations. The cell performance and operating data, including cell voltage and resistance, were measured, and neutron radiographs were recorded… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2017
2017
2022
2022

Publication Types

Select...
6

Relationship

2
4

Authors

Journals

citations
Cited by 9 publications
(3 citation statements)
references
References 33 publications
0
3
0
Order By: Relevance
“…The channels of the bipolar plates are posed in a cross‐flow layout, with vertical channels in the anode and horizontal channels in the cathode. This configuration is actually the result of rotating 90° the original position of the cell, as previous results shown that this orientation was increasing the cell performance .…”
Section: Methodsmentioning
confidence: 99%
“…The channels of the bipolar plates are posed in a cross‐flow layout, with vertical channels in the anode and horizontal channels in the cathode. This configuration is actually the result of rotating 90° the original position of the cell, as previous results shown that this orientation was increasing the cell performance .…”
Section: Methodsmentioning
confidence: 99%
“…The horizontally located channels along with upper side inlet manifolds showed the lowest pressure drop cum parasitic losses, easy water removal and higher performance. The serpentine multi‐pass channels with horizontal and vertical orientations were investigated and found that the cell with horizontal orientation gave better performance (voltage gain of 20–35 mV at 10 A), superior membrane hydration and lower liquid blockages than the vertical orientation [89] …”
Section: Effects Of Different Flow Field Designsmentioning
confidence: 99%
“…Intensive research efforts are carried out in order to investigate the most performing flow field layouts [2,[12][13][14][15][16][17][18], configurations (co-flow, counter-flow) [2,[19][20][21][22] and orientations (vertical or horizontal channels, horizontal facing upwards or downwards) [15,[23][24][25][26][27].…”
Section: Introductionmentioning
confidence: 99%