2013
DOI: 10.1016/j.ijheatmasstransfer.2013.04.034
|View full text |Cite
|
Sign up to set email alerts
|

Effect of size on ground-coupled heat pump performance

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
9
0

Year Published

2015
2015
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 14 publications
(9 citation statements)
references
References 13 publications
0
9
0
Order By: Relevance
“…Miniaturization is not the only requirement of MVCR; one of the most important points is how to achieve excellent cooling performance based on the miniaturization of the system. It is well known that larger systems are generally more thermodynamically efficient than smaller systems, which can be verified by the correlation of Alalaimi et al [5]; therefore, one of the main objectives of the project is to develop a numerical model to characterize the behaviour of an MVCR. Then, the most relevant parameters are In the condenser and evaporator HXs, heat is transferred between the refrigerant fluid and the heat source and dissipating medium fluids, known as secondary fluids.…”
Section: State Of the Artmentioning
confidence: 84%
“…Miniaturization is not the only requirement of MVCR; one of the most important points is how to achieve excellent cooling performance based on the miniaturization of the system. It is well known that larger systems are generally more thermodynamically efficient than smaller systems, which can be verified by the correlation of Alalaimi et al [5]; therefore, one of the main objectives of the project is to develop a numerical model to characterize the behaviour of an MVCR. Then, the most relevant parameters are In the condenser and evaporator HXs, heat is transferred between the refrigerant fluid and the heat source and dissipating medium fluids, known as secondary fluids.…”
Section: State Of the Artmentioning
confidence: 84%
“…Research on the optimization of the parameters of the \ground heat exchanger-heat pump" has been conducted by scientists in France (Toulouse) and the USA (Denver) [10]. As the objective function is adopted with respect to cost, the calculation is carried out and the optimal size for the speci c HP ground heat exchangers is determined.…”
Section: State Of the Problemmentioning
confidence: 99%
“…The more important point is how to achieve excellent cooling performance on the basis of system miniaturization. It is known that the larger systems generally are more efficient thermodynamically than the smaller systems, which can be proven by the correlation by Alaimimi et al on the relation of revisable efficiency (the second law efficiency) versus system size [24]. This in turn introduces higher requirements and more difficulties for the system miniaturization.…”
Section: Introductionmentioning