Abstract:By using a new type pure rolling fatigue test rig with three contact points for silicon nitride bearing ball specimen, the contact deflection angle of specimen with three contact points is calculated. The effects of the center height and test ball radius on the specimen contact deflection angle are analyzed. The analysis indicates that the span of contact deflection angle is 0-0.181° while the center height is 1.2mm and the design radius is 6.35mm and the specimen radiuses change from 4mm to 8mm. The more cont… Show more
Set email alert for when this publication receives citations?
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.