2020
DOI: 10.1016/j.eti.2020.101106
|View full text |Cite
|
Sign up to set email alerts
|

Effect of wastewater depth to the performance of short-term batching-experiments horizontal flow constructed wetland system in treating domestic wastewater

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
8
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
6
1
1

Relationship

2
6

Authors

Journals

citations
Cited by 35 publications
(9 citation statements)
references
References 52 publications
0
8
0
Order By: Relevance
“…Ammonia concentration in Indonesia was 0.7-20 mg/l in grey water and 112 mg/l in black water. In mixed wastewater, ammonia concentration was 0.1-259 mg/l; the mean (45 mg/l) was higher but within the same order of magnitude with similar streams in Malaysia (12 mg/l) and Vietnam (36 mg/l) (Al-Ajalin et al 2020;Tra et al 2021). Total nitrogen concentration in Indonesia was 59-226 mg/l in grey water, 35-192 mg/l in mixed wastewater and 112 mg/l in black water.…”
Section: Nitrogen and Phosphorusmentioning
confidence: 75%
See 1 more Smart Citation
“…Ammonia concentration in Indonesia was 0.7-20 mg/l in grey water and 112 mg/l in black water. In mixed wastewater, ammonia concentration was 0.1-259 mg/l; the mean (45 mg/l) was higher but within the same order of magnitude with similar streams in Malaysia (12 mg/l) and Vietnam (36 mg/l) (Al-Ajalin et al 2020;Tra et al 2021). Total nitrogen concentration in Indonesia was 59-226 mg/l in grey water, 35-192 mg/l in mixed wastewater and 112 mg/l in black water.…”
Section: Nitrogen and Phosphorusmentioning
confidence: 75%
“…Grey water samples were collected at residential outlets (Jiawkok et al 2013;Suoth and Nazir 2016;Hafiza et al 2019) or wastewater treatment plant (WWTP) inlets (Astika and Zaman 2017;Marleni et al 2020). Mixed wastewater samples were collected at WWTP inlets except in three studies (Nagu and Lessy 2020;Al-Ajalin et al 2020;Ratnawati and Sugito 2021) where they were collected at residential outlets. Black water samples were collected at residential outlets (Hafiza et al 2019) and WWTP inlets (Rochmadi et al 2010).…”
Section: Domestic Wastewater Characteristicsmentioning
confidence: 99%
“…pH maintained a mean within the neutral levels throughout the duration of the experiment in all mesocosms (planted and unplanted), as it ranged between 7.5 ± 0.05 to 7.8 ± 0.04 for both pollutants. According to Al-Ajalin et al. (2020) who reported only a slight increment over the initial pH value (6.35 ± 0.35), neutral pH rates (6–9) were essential for plant maintenance and bacterial growth within subsurface flow CWs.…”
Section: Resultsmentioning
confidence: 99%
“…Lastly, the greatest challenge for this technology is its introduction at a larger scale for industrial applications [ 193 , 194 ]. The green technology, in industry, is currently growing and capturing considerable attention due to the toxic impacts of conventional coagulation.…”
Section: Limitations and Future Challengesmentioning