Effects of capillary discharge current on the time of lasing onset of soft x-ray laser at low pressure

Abstract: The laser spike of Ne-like argon 46.9 nm pumped by a capillary discharge is measured with an x-ray diode (XRD) at low Ar pressure (25 Pa). Changing the rise-time and amplitude of the main current, we observe the effects of current on the time of the laser spike. The experimental results show that the time of lasing onset, which is the time of the laser spike after the onset of the main current, is larger than 40 ns and almost constant when the rise-time and amplitude of the current are changed. The theoretical… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
13
0

Year Published

2010
2010
2016
2016

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 45 publications
(13 citation statements)
references
References 12 publications
(22 reference statements)
0
13
0
Order By: Relevance
“…1b. The spike of Xe plasma emission is wider than the 46.9 nm laser spike (~2 ns) [11,12] in pulse duration. Therefore, the spike of Xe plasma emission should be carefully studied to make certain whether it is a laser spike or not.…”
mentioning
confidence: 85%
See 1 more Smart Citation
“…1b. The spike of Xe plasma emission is wider than the 46.9 nm laser spike (~2 ns) [11,12] in pulse duration. Therefore, the spike of Xe plasma emission should be carefully studied to make certain whether it is a laser spike or not.…”
mentioning
confidence: 85%
“…Experiment Setup. This experiment was conducted with the apparatus described in [11], in which Ne-like Ar 46.9 nm [11] and 69.8 nm [3] laser output pumped by a capillary discharge has been reported. The capillary is 3 mm in inner diameter and 35 cm in length.…”
mentioning
confidence: 99%
“…The capillary discharge setup used to conduct the experiments was described in the previous publications [23,24]. The main pulse generator consists of a 7 nF Blumlein line filled with de-ionized water.…”
Section: Methodsmentioning
confidence: 99%
“…This soft X-ray lasing demands optimization of various parameters which include: discharge current amplitude, its rate of rise (dI/dt), initial gas pressure, pre-pulse conditions (pre-pulse amplitude and its timing with respect to the discharge current) and the capillary dimensions (length and inner diameter). Various studies had been made to understand the effect of some of these parameters like (1) gas pressure, (2) pre-pulse amplitude and its delay with respect to the main pulse and (3) current pulse duration on the output of capillary discharge X-ray laser [12,13,29,30]. Apart from these parameters, the capillary tube material has also an important role to play.…”
Section: Introductionmentioning