Abstract:The effect of different cooling conditions on the formation of Martensite-Austenite (MA) in a High - Strength Low - Alloy (HSLA) steel was assessed. The MA constituent is detrimental to impact toughness in pipeline applications, so the purpose of this research was to minimize its presence through the choice of effective cooling media and optimal parameters such as the cooling rate and final cooling temperature. The volume fraction, size and morphology of MA was evaluated by selective etching and corroborated t… Show more
Set email alert for when this publication receives citations?
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.