Effects of Cooling Tower Performance to Water Cooled Chiller Energy Use: a Case Study toward Energy Conservation of Office Building

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
2
0
4

Year Published

2019
2019
2024
2024

Publication Types

Select...
4
1
1

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(6 citation statements)
references
References 16 publications
0
2
0
4
Order By: Relevance
“…The two variable speed chilled water pumps (One Duty and One Standby) are utilized to maintain the circulation of the chilled water between the chiller evaporator and the terminal units which consist of FCUs (Two-Pipe and Four-Pipe FCUs) and AHUs. The terminal units absorb the heat from the spaces inside the building which results in an increase of the chilled water temperature that returns to the chiller evaporator to transfer heat to the refrigerant and then supplied back to the terminal units (Suamir, et al, 2018).…”
Section: The Central Cooling Plantmentioning
confidence: 99%
“…The two variable speed chilled water pumps (One Duty and One Standby) are utilized to maintain the circulation of the chilled water between the chiller evaporator and the terminal units which consist of FCUs (Two-Pipe and Four-Pipe FCUs) and AHUs. The terminal units absorb the heat from the spaces inside the building which results in an increase of the chilled water temperature that returns to the chiller evaporator to transfer heat to the refrigerant and then supplied back to the terminal units (Suamir, et al, 2018).…”
Section: The Central Cooling Plantmentioning
confidence: 99%
“…Analisa dilakukan untuk dapat memberikan wawasan tentang kinerja menara pendingin, kehilangankan energi dan alternative perbaikan. Banyak penelitian telah dilakukan untuk menganalisa kinerja menara pendingin dan hasilhasil penelitian tersebut digunakan sebagai referensi dalam penulisan artikel ini [5][6][7][8][9].…”
Section: Pendahuluanunclassified
“…Dimana : COC = Cycle of Concentration ditentukan 5 [9] 2.7. Drift (D) Merupakan tetesan air yang terperangkap di aliran udara yang akan hilang bersama udara.…”
Section: (6)unclassified
“…Gambar 11. Grafik Debit aliran vs kapasitas pendinginan Kapasitas pendinginan suatu cooling tower adalah setara dengan kemampuan cooling tower tersebut dalam membuang kalor ke udara sekitar atau lingkungan cooling tower [11,12]. Dari hasil penelitian menunjukkan bahwa, makin besar debit aliran air ke cooling tower, maka kapasitas pendinginan dari cooling tower tersebut makin meningkat.…”
Section: Grafik Debit Aliran Vs Kapasitaspendinginanunclassified