2018
DOI: 10.1016/j.cep.2018.04.031
|View full text |Cite
|
Sign up to set email alerts
|

Effects of intensification on process features and control properties of lignocellulosic bioethanol separation and dehydration systems

Abstract: Highlights  Study the new intensified systems for actual bioethanol broth separation and purification  Process features and control properties for the intensified systems were analyzed  Intensified systems with cost savings and competitive control properties were identified  New information for promoting the implementation of the intensified systems

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

2
1
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
4
2
1

Relationship

2
5

Authors

Journals

citations
Cited by 14 publications
(3 citation statements)
references
References 50 publications
2
1
0
Order By: Relevance
“…Table shows how the reboiler duty rises when considering the oligomerization column, i.e., the overall process consumes a greater amount of energy when including this reactive column. This behavior has been observed in some other case studies (Torres-Ortega et al, 2018) . In this sense, many of the indicators that depend on reboiler duty suffer a detriment.…”
Section: Resultssupporting
confidence: 72%
See 1 more Smart Citation
“…Table shows how the reboiler duty rises when considering the oligomerization column, i.e., the overall process consumes a greater amount of energy when including this reactive column. This behavior has been observed in some other case studies (Torres-Ortega et al, 2018) . In this sense, many of the indicators that depend on reboiler duty suffer a detriment.…”
Section: Resultssupporting
confidence: 72%
“…This behavior has been observed in some other case studies (Torres-Ortega et al, 2018). 64 In this sense, many of the indicators that depend on reboiler duty suffer a detriment. For example, the fact that a large amount of energy is required in the reboiler without any improvement in performance or product yield is indicative of a detriment to thermodynamic efficiency.…”
Section: Resultsmentioning
confidence: 99%
“…However, the scheme with the highest level of intensification (scheme J), even though at low frequencies presents relatively good dynamic behavior, is not actually the best one. In other words, as long as the high level of intensification is reached, not always the best dynamic properties may be obtained, a similar conclusion is obtained in the application of intensification techniques applied to ethanol purification [55]. Nevertheless, the scheme J), is competitive regarding IR, green metrics, and dynamic properties in comparison with the other alternatives.…”
Section: Discussionsupporting
confidence: 57%