2010
DOI: 10.1007/s00417-010-1346-5
|View full text |Cite
|
Sign up to set email alerts
|

Effects of luminance combinations on the characteristics of the global flash multifocal electroretinogram (mfERG)

Abstract: The g/f ratio is important in the MOFO mfERG paradigm, since the DC and IC responses change with this ratio. In order to obtain both optimal DC and IC responses, a g/f ratio of 1:1 with focal flash luminance between 100 cd/m(2) and 200 cd/m(2) would be recommended. As the global flash mfERG paradigm is studying the interaction triggered by both flashes, the g/f ratio is a vital parameter for measurement in future studies.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
6
0

Year Published

2011
2011
2015
2015

Publication Types

Select...
5

Relationship

2
3

Authors

Journals

citations
Cited by 5 publications
(6 citation statements)
references
References 21 publications
0
6
0
Order By: Relevance
“…All the grating patterns had the same number of black and white strips within each mfERG hexagonal stimulus and hence the measured luminance of different grating patterns was the same. The ratio of global flash to focal flash was maintained at 1:1 in this study to obtain both optimal DC and IC responses [ 45 ]. The MOFO mfERG results in a direct component (DC) and an induced component (IC) which can be separately measured to assess the outer and inner retinal responses.…”
Section: Methodsmentioning
confidence: 99%
“…All the grating patterns had the same number of black and white strips within each mfERG hexagonal stimulus and hence the measured luminance of different grating patterns was the same. The ratio of global flash to focal flash was maintained at 1:1 in this study to obtain both optimal DC and IC responses [ 45 ]. The MOFO mfERG results in a direct component (DC) and an induced component (IC) which can be separately measured to assess the outer and inner retinal responses.…”
Section: Methodsmentioning
confidence: 99%
“…The background luminance of the mfERG display was 100cd/m 2 . At the high contrast level (98%), both the luminance of the bright phase of the multifocal stimulus and the global flashes were set at 200cd/m 2 as suggested by our previous study, in order to obtain optimal DC and IC responses [23]. The dark phase was set at a luminance of 2cd/m 2 .…”
Section: Stimulus Conditionsmentioning
confidence: 99%
“…A VERIS Science 5.1 system (Electro-Diagnostic-Imaging, Redwood City, CA, USA) was used for the MOFO mfERG measurement. The instrumental set-up was similar to that described in our previous studies [32,34,35]. Briefly, the mfERG stimulation was a 103 scaled hexagonal pattern which subtended 47° horizontally and 44° vertically.…”
Section: Measurement 1) Mferg Stimulation and Recordingmentioning
confidence: 99%