2017
DOI: 10.2147/opth.s143427
|View full text |Cite
|
Sign up to set email alerts
|

Effects of temperature and fluid media on the scroll width size of the Descemet’s membrane endothelial keratoplasty (DMEK) donor graft

Abstract: AimOur study was conducted to evaluate whether higher temperature leads to increased – or wider – scroll widths of the Descemet’s membrane endothelial keratoplasty (DMEK) donor graft.PurposeTo investigate the effects of temperature and fluid media on the DMEK donor graft scroll widths.Materials and methodsThis research work was a laboratory investigation. Baseline cell count was taken via specular microscopy for the donor corneas at room temperature (20°C–25°C). The endothelium sides of the donor corneas were … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
10
1
2

Year Published

2018
2018
2023
2023

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 13 publications
(13 citation statements)
references
References 20 publications
0
10
1
2
Order By: Relevance
“…Während im Labor durch Degradierung der elastischen Fasern der Spenderlamelle mit Elastase die Rollneigung aufgehoben werden konnte [8], ist die klinische Anwendung der Elastase fraglich. Hinweise dafür, dass auch Temperaturunterschiede einen Einfluss auf die Transplantatrolle haben, fanden Koo et al in einer kleinen Fallserie mit je 3 Spenderlamellen [9].…”
Section: Resultsunclassified
See 1 more Smart Citation
“…Während im Labor durch Degradierung der elastischen Fasern der Spenderlamelle mit Elastase die Rollneigung aufgehoben werden konnte [8], ist die klinische Anwendung der Elastase fraglich. Hinweise dafür, dass auch Temperaturunterschiede einen Einfluss auf die Transplantatrolle haben, fanden Koo et al in einer kleinen Fallserie mit je 3 Spenderlamellen [9].…”
Section: Resultsunclassified
“…Die Ergebnisse widersprechen damit der Untersuchung von Koo et al, die bei steigender Temperatur eine Zunahme des Transplantatrollen-Durchmessers beobachteten [9]. Da methodisch ähnlich vorgegangen wurde, bleibt der Grund hierfür unklar.…”
Section: Ergebnisseunclassified
“…Also, it has been postulated that donor lens status influences the outcome of the DMEK surgery [ 11 ]. Another interesting aspect is the role of the culture media on endothelial cell viability and its effect on the actual scroll width during surgery [ 12 ]. However, the previous studies include either a small number of eyes or only present short-term results.…”
Section: Introductionmentioning
confidence: 99%
“…Type (hypothermic or organ culture), composition, storage temperature, days and in particular, storing DMEK tissues at higher temperature have shown increased scroll width. [ 5 ] Composition of DM. In relation to tissue's elastic properties, impact of storage media and conditions of collagen and elastin in the banded and non-banded zones of DM has also been reported to have an impeding effect on DMEK scrolling and unscrolling.…”
mentioning
confidence: 99%
“…Type (hypothermic or organ culture), composition, storage temperature, days and in particular, storing DMEK tissues at higher temperature have shown increased scroll width. [ 5 ]…”
mentioning
confidence: 99%