2005
DOI: 10.1016/j.nima.2004.09.028
|View full text |Cite
|
Sign up to set email alerts
|

Efficiency optimization of microchannel plate (MCP) neutron imaging detectors. I. Square channels with 10B doping

Abstract: Microchannel plate (MCP) event-counting imaging detectors with very high spatial resolution (~10 µm) and timing accuracy (~100 ps) are widely employed for the detection and imaging applications of electrons and ions, as well as UV and X-ray photons.Recently it was demonstrated that the many advantages of MCPs are also applicable to neutron detection with high 2-dimensional spatial resolution. Boron, enriched in the isotope 10 B, was added to the MCP glass structure to enhance the neutron interaction within the… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
63
0
1

Year Published

2015
2015
2023
2023

Publication Types

Select...
7
3

Relationship

0
10

Authors

Journals

citations
Cited by 108 publications
(64 citation statements)
references
References 17 publications
0
63
0
1
Order By: Relevance
“…Preliminary experimental tests indicate that this technique could be also employed by using boron coating a CMOS device. CCD and CMOS devices with timing resolutions of about 1 s are used in neutron imaging applications [21][22][23][24] and are commercially available. The mentioned devices will also allow to use this technique in neutron time-of-flight measurements.…”
Section: Resultsmentioning
confidence: 99%
“…Preliminary experimental tests indicate that this technique could be also employed by using boron coating a CMOS device. CCD and CMOS devices with timing resolutions of about 1 s are used in neutron imaging applications [21][22][23][24] and are commercially available. The mentioned devices will also allow to use this technique in neutron time-of-flight measurements.…”
Section: Resultsmentioning
confidence: 99%
“…For this experiment, a time resolution of 4.48 μswasset.TheMCPhasa detection efficiency of approximately 50% for neutron energy ranges relevant for to this study [49]. Details of the detector and its specifications can be found elsewhere [48,50].…”
Section: Bragg Edge Imagingmentioning
confidence: 99%
“…Again, the cost, size and complexity of such an imaging system greatly impacts the application space. The Microchannel Plate (MCP) technology was adapted to neutron detection by integrating 10 B in the glass channel sidewall [8]. Coupled to a high resolution ASIC (application specific integrated circuit), the MCP has shown high speed detection windows at a resolution of roughly 10 µm, limited by the channel pore distance [9,10].…”
Section: Indirect Neutron Detectionmentioning
confidence: 99%