2019
DOI: 10.1051/e3sconf/201912402020
|View full text |Cite
|
Sign up to set email alerts
|

Efficiency study of the reactive shunt compensation device in power lines

Abstract: We consider the devices for reactive shunt compensation and simulated their use in a real energy facility.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
5
0

Year Published

2020
2020
2021
2021

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 8 publications
(5 citation statements)
references
References 2 publications
0
5
0
Order By: Relevance
“…A thorough analysis of the above diagrams may be used to construct optimal high voltage cables used in the ignition systems of spark−ignition engines, where the most important parameter is the U 2 voltage modulus [3,4,10,20].…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…A thorough analysis of the above diagrams may be used to construct optimal high voltage cables used in the ignition systems of spark−ignition engines, where the most important parameter is the U 2 voltage modulus [3,4,10,20].…”
Section: Discussionmentioning
confidence: 99%
“…Their values are specified as Ω/m, S/m, H/m, and F/m [7][8][9]. It is conventionally assumed that if l is greater than 0.1 λ, or the transmission of impulse signals with a short rise time, as is the case in high voltage cables of spark ignition engines [3,4,6,10], then such a line should be treated as a circuit with distributed parameters. This paper shall examine the properties of a homogeneous line, whose primary parameters are uniformly distributed along the line [7,9].…”
Section: Linear Circuits With Distributed Parametersmentioning
confidence: 99%
See 1 more Smart Citation
“…Potential difference from EOD and EOMP devices is supplied on the winding conductors and the transformer housing. Therefore, EOD and EOMP for transformers require special consideration [23].…”
Section: Introductionmentioning
confidence: 99%
“…Active electro-technical network equipment (FACTS) is capable of flexibly change the characteristics of electric power transmission or conversion in order to optimize grid modes at once according to several criteria: throughput, technological loss level, stability, redistribution of power flows, power quality, etc. [1] FACTS devices enable not only successful compensation of reactive power in the power grid, but also adequate response to abnormal conditions in it. Thanks to these parameters, flexible AC transmission systems are one of the best devices to be installed in line.…”
Section: Introductionmentioning
confidence: 99%