2021
DOI: 10.1109/access.2021.3129821
|View full text |Cite
|
Sign up to set email alerts
|

Efficient Day-Ahead Scheduling Voltage Control Scheme of ULTC and Var of Distributed Generation in Distribution System

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...

Citation Types

1
9
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
2

Relationship

1
1

Authors

Journals

citations
Cited by 2 publications
(10 citation statements)
references
References 30 publications
1
9
0
Order By: Relevance
“…In the above article [1], the simulation for CASE 2 contained technical mistakes. First, the scenario data for the simulation included errors caused by technical mistakes in the process of generating the scenarios according to the forecast error levels of the distributed generators (DGs) and loads.…”
mentioning
confidence: 99%
See 4 more Smart Citations
“…In the above article [1], the simulation for CASE 2 contained technical mistakes. First, the scenario data for the simulation included errors caused by technical mistakes in the process of generating the scenarios according to the forecast error levels of the distributed generators (DGs) and loads.…”
mentioning
confidence: 99%
“…1) In [1,Table 12,], the PI values for the comparison between the conventional control schemes and the proposed control scheme were miscalculated in the program calculation process. This was expressed as a value 10× larger than the normal calculated value.…”
mentioning
confidence: 99%
See 3 more Smart Citations