2021
DOI: 10.1016/j.egyr.2021.09.041
|View full text |Cite
|
Sign up to set email alerts
|

Efficient use of heat from CHP distributed by district heating system in district cooling networks

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
6
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
8

Relationship

2
6

Authors

Journals

citations
Cited by 16 publications
(6 citation statements)
references
References 8 publications
0
6
0
Order By: Relevance
“…The next cluster in yellow focuses on heating and cooling appliances with keywords such as "heating", "cooling systems", and "absorption cooling". In this cluster, we can also find the keywords "carbon dioxide emissions" and "renewable energy" which demonstrate the efforts being made to transform the energy demand matrix of these highly energyintensive appliances into renewable energy [23][24][25][26].…”
Section: Analysis Of Abstractmentioning
confidence: 99%
“…The next cluster in yellow focuses on heating and cooling appliances with keywords such as "heating", "cooling systems", and "absorption cooling". In this cluster, we can also find the keywords "carbon dioxide emissions" and "renewable energy" which demonstrate the efforts being made to transform the energy demand matrix of these highly energyintensive appliances into renewable energy [23][24][25][26].…”
Section: Analysis Of Abstractmentioning
confidence: 99%
“…In the case of Tallinn, the second priority option after free cooling will be the cold supply using the heat rejected by biomass CHPs in the summer. Cold supply via absorption chillers using rejected heat from a CHP that was transferred through the district heating network was analysed in detail in a previous study [25].…”
Section: Cold Supply Planning For District Coolingmentioning
confidence: 99%
“…A heat pump evaporator can be used for cooling in a district cooling system while simultaneously producing heat in the district heating system [24]. Another option is to use summer excess heat from combined heat and power (CHP) plants to produce cold via absorption chillers [25][26][27]. This is a good solution, as the CHP plants would otherwise have to be shut down due to the lack of summer heat load.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…In the Ülemiste district of Tallinn, a DC network is being constructed that will use the excess heat from the Tallinn CHP plant [33]. According to the absorption chiller datasheet, the cooling capacity corresponds to the temperature at the hot water inlet, where a 39% loss in cooling capacity is indicated when the driving hot water temperature is lowered to 77 • C. This study hereby investigates the roots of these problems.…”
Section: Introductionmentioning
confidence: 99%