2011
DOI: 10.1002/biot.201000105
|View full text |Cite
|
Sign up to set email alerts
|

Elastic phantoms generated by microfluidics technology: Validation of an imaged‐based approach for accurate measurement of the growth rate of lung nodules

Abstract: This paper focuses on validating our approach for monitoring the development of lung nodules detected in successive chest low-dose computed tomography (LDCT) scans of a patient. Our methodology for monitoring detected lung nodules includes 3D LDCT data registration, which is a non-rigid technique and involves two steps: (i) global target-to-prototype alignment of one scan to another using the experience gained from a prior appearance model, followed by (ii) local alignment to correct for intricate relative def… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2013
2013
2021
2021

Publication Types

Select...
5
1
1

Relationship

2
5

Authors

Journals

citations
Cited by 25 publications
(5 citation statements)
references
References 31 publications
0
5
0
Order By: Relevance
“…Another trend describes the lung nodule's shape by representing its 3D surface with a linear combination of spherical harmonics (SH) [247, 355358]. The recent works suggested employing different types of appearance and shape features to achieve better detection and diagnosis of lung nodules.Investigations of using the microfluidics technology to mimic the contractions and expansions of the lung and nodules during normal breathing have recently been explored to provide more realistic phantoms in order to validate the volumetric growth rate measurements [305307]. …”
Section: Discussionmentioning
confidence: 99%
See 3 more Smart Citations
“…Another trend describes the lung nodule's shape by representing its 3D surface with a linear combination of spherical harmonics (SH) [247, 355358]. The recent works suggested employing different types of appearance and shape features to achieve better detection and diagnosis of lung nodules.Investigations of using the microfluidics technology to mimic the contractions and expansions of the lung and nodules during normal breathing have recently been explored to provide more realistic phantoms in order to validate the volumetric growth rate measurements [305307]. …”
Section: Discussionmentioning
confidence: 99%
“…Investigations of using the microfluidics technology to mimic the contractions and expansions of the lung and nodules during normal breathing have recently been explored to provide more realistic phantoms in order to validate the volumetric growth rate measurements [305307]. …”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…However, this "gold standard" ground truth may not be accurate due to hand shaking and observer's variability. Additionally, several studies (e.g., [21][22][23]) evaluated the accuracy and limitations of a number of commercial segmentation packages that have been released by CT vendors. To overcome these limitations, we introduce a validation approach that generates 3D realistic phantoms to validate our developed segmentation approach [24,25].…”
Section: Introductionmentioning
confidence: 99%