2023
DOI: 10.1016/j.carbon.2022.12.016
|View full text |Cite
|
Sign up to set email alerts
|

Electrically aligned Ti3C2Tx MXene composite with multilayered gradient structure for broadband microwave absorption

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
5
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 23 publications
(5 citation statements)
references
References 50 publications
0
5
0
Order By: Relevance
“…Chen et al 96 created a parallel plate structure of the Ti 3 C 2 T x -MXene filler within an epoxy matrix using an electric field-assisted orientation technique. To optimize impedance matching, they designed a multilayer composite structure based on oriented MXene/epoxy composites.…”
Section: Design Optimization Of Mxene Composite Ma Materialsmentioning
confidence: 99%
“…Chen et al 96 created a parallel plate structure of the Ti 3 C 2 T x -MXene filler within an epoxy matrix using an electric field-assisted orientation technique. To optimize impedance matching, they designed a multilayer composite structure based on oriented MXene/epoxy composites.…”
Section: Design Optimization Of Mxene Composite Ma Materialsmentioning
confidence: 99%
“…They can be expressed as M n +1 X n T x , where M represents an early transition metal, X can be carbon and/or nitrogen, T refers to surface functional groups (−OH, –O, –F, etc. ), and n = 1, 2, 3, or 4. Ti 3 C 2 T x MXene is one of the most studied MXenes, which is generally produced by the room temperature Al etching of Ti 3 AlC 2 by hydrofluoric acid (HF). Due to the excellent physical and chemical properties of Ti 3 C 2 T x MXene, such as good chemical properties, high electrical conductivity, outstanding mechanical properties, large specific surface area, and rich surface functional groups, Ti 3 C 2 T x MXene has proven to be a promising candidate for electrochemical and flexible sensors. , …”
Section: Introductionmentioning
confidence: 99%
“…2 Thus, it is necessary to develop a simple, rapid, highly selective and sensitive method for the detection of FZD residues. 3 At present, high performance liquid chromatography, 4 liquid chromatographymass spectrometry, 5 triple tandem liquid chromatographymass spectrometry 6 and enzyme-linked immunoassay 7 have been used for the detection of FZD. However, shortcomings such as time-consuming, expensive, and complex equipment, complicated sample preparation and difficulty in field inspection limit the wide application of the above traditional methods.…”
Section: Introductionmentioning
confidence: 99%