2010
DOI: 10.1016/j.bios.2010.08.030
|View full text |Cite
|
Sign up to set email alerts
|

Electrochemical detection of foodborne pathogen Aeromonas hydrophila by DNA hybridization biosensor

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

1
31
0

Year Published

2012
2012
2016
2016

Publication Types

Select...
6
2
1

Relationship

0
9

Authors

Journals

citations
Cited by 53 publications
(32 citation statements)
references
References 24 publications
1
31
0
Order By: Relevance
“…The final applications include biomedical diagnostics [1][2][3], environmental [4] and food control [5,6], and safety and biohazard assessment [7,8]. In practice, unique characteristics distinguish (bio)electrochemical sensors from classical instrumental methods, for example spectroscopy, chromatography, and mass spectrometry; these include low cost, miniaturizability, ease of use, no interference from coloured or turbid samples, and applicability to raw samples for "in situ" and decentralized.…”
Section: Introductionmentioning
confidence: 99%
“…The final applications include biomedical diagnostics [1][2][3], environmental [4] and food control [5,6], and safety and biohazard assessment [7,8]. In practice, unique characteristics distinguish (bio)electrochemical sensors from classical instrumental methods, for example spectroscopy, chromatography, and mass spectrometry; these include low cost, miniaturizability, ease of use, no interference from coloured or turbid samples, and applicability to raw samples for "in situ" and decentralized.…”
Section: Introductionmentioning
confidence: 99%
“…The ssDNA used in this work is a 20-mer oligonucleotides sequence that has been previously verified and reported to have high selectivity and specificity to A. hydrophila aerolysin gene [27]. A. hydrophila is a highly epidemic pathogen, mostly distributed in aquatic environments and food.…”
Section: A N U S C R I P Tmentioning
confidence: 99%
“…In all of them labeled ssDNA were used which has a difficult and expensive biochemical preparation [27,32,33].In this study, we used a new methodology for immobilization of ssDNA sequence on glassy carbon electrode. Reduced graphene oxide decorated cerium oxide nanocomposite/Polyaniline/glassy carbon electrode [CeO 2 NPs-RGO/PANI/GCE] was fabricated as a platform for immobilization of ssDNA sequence.…”
Section: A N U S C R I P Tmentioning
confidence: 99%
“…Electrochemical DNA sensors have been used in food safety monitoring and the detection of pathogen DNA. Tichoniuk et al described an electrochemical DNA biosensor for the detection of Aeromonas hydrophila with a mixed self-assembled monolayer-modified electrode [29]. Ligaj et al presented two kinds of electrochemical DNA sensor for the detection of pathogenic bacteria [30].…”
Section: Introductionmentioning
confidence: 99%