2021
DOI: 10.1016/j.sbsr.2021.100445
|View full text |Cite
|
Sign up to set email alerts
|

Electrochemical immunosensor for detection of CA 15-3 biomarker in point-of-care

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
13
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 22 publications
(14 citation statements)
references
References 38 publications
1
13
0
Order By: Relevance
“…This chip, including gold screen-printed electrodes, was utilized to create a portable device for keeping an eye on the oncomarker in a POCT for a medical setting. Low detection levels (LOD: 0.95 U/mL) and a broad linear concentration range (1.0 to 1000 U/mL) were both accomplished by the sophisticated biosensor [ 75 ]. Martin and his colleagues created a sandwich-type EI with a low LOD of 0.08 fg/mL.…”
Section: Electrochemical Biosensors Based On Nanostructured Materials...mentioning
confidence: 99%
“…This chip, including gold screen-printed electrodes, was utilized to create a portable device for keeping an eye on the oncomarker in a POCT for a medical setting. Low detection levels (LOD: 0.95 U/mL) and a broad linear concentration range (1.0 to 1000 U/mL) were both accomplished by the sophisticated biosensor [ 75 ]. Martin and his colleagues created a sandwich-type EI with a low LOD of 0.08 fg/mL.…”
Section: Electrochemical Biosensors Based On Nanostructured Materials...mentioning
confidence: 99%
“…Label-Free EC Immunosensors for Cancer Antigen 15-3 (CA 15-3) Detection CA 153 is a glycoprotein belonging to mucin 1 family. It is present in healthy human beings at a level lower than 30 U/mL and is a major serum oncomarker for breast cancer used for both detection and follow-up [76,77]. It is also used in cases of ovarian cancer [16,78] as it's level is heightened in about 70% of patients with epithelial ovarian cancer with most of the disease being in an advanced stage [78].…”
Section: Label-free Ec Immunosensors For P53 Detectionmentioning
confidence: 99%
“…The use of antibody-type biological components in the fabrication of electrochemical immunosensors represented the starting point for the development of this field ensuring promising perspectives for the biomedical domain. The presence of antibodies in the structure of electrochemical biosensors allowed the extraordinary improvement of the analytical performances in terms of selectivity for the target, this being mainly due to the specific antigen–antibody interaction [ 22 , 33 , 35 , 39 , 46 , 62 ].…”
Section: Biomarkers Involved In Inflammatory Diseasesmentioning
confidence: 99%
“…Thus, an innovative portable immunosensor based on a gold chip-type transducer functionalized with a self-assembled monolayer of mercaptosuccinic acid was designed for the detection of the CA 15–3. The covalent immobilization of the CA 15–3–specific antibodies via EDC/NHS chemistry with the carboxyl groups provided by the polymer ensured the selectivity of the immunosensor for the target protein in serum [ 33 ]. In another study, antibody immobilization is performed by interaction with the functions present on the composite film based on core/shell CdSe@ZnSQD, which also acts as an electroactive label, for the detection of HER2 in spiked serum [ 46 ].…”
Section: Biomarkers Involved In Inflammatory Diseasesmentioning
confidence: 99%