2022
DOI: 10.1016/j.jwpe.2022.102584
|View full text |Cite
|
Sign up to set email alerts
|

Electrocoagulation in the dual application on the simultaneous removal of fluoride and nitrate anions through respective adsorption/reduction processes and modelling of continuous process

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
10
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6
1
1

Relationship

0
8

Authors

Journals

citations
Cited by 23 publications
(10 citation statements)
references
References 80 publications
0
10
0
Order By: Relevance
“…% Removal efficiency = (5) where C 0 is the initial COD and TP value (mg/L), C t is the COD and TP value at t time.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…% Removal efficiency = (5) where C 0 is the initial COD and TP value (mg/L), C t is the COD and TP value at t time.…”
Section: Methodsmentioning
confidence: 99%
“…EC is one of the treatment methods that can be used to remove high organic pollutants. EC was tested successfully to treat fluoride [5], polyvinyl alcohol [6,7], phenol [8], tannery [9], arsenic [10], humic substance [11], hydroquinone [12], and boron [13]. EC has also been proposed to treat various food industry wastewaters such as card boast [14], offset printing wastewater [15], landfill leachate [16], drinking water [17,18], textile wastewater [19], and olive mill wastewater [20].…”
Section: Introductionmentioning
confidence: 99%
“…The quadratic model was chosen for further analysis because it yielded good adjusted and predicted R 2 values. The RE% in terms of several independent variables is calculated using the design response variable in the model, as expressed in eqn (8). Thus, the Design-Expert software was used to develop the equation in coded factors, which can further predict the response behavior for each factor level.…”
Section: Model Fit and Statistical Analysismentioning
confidence: 99%
“…Various technologies have been developed and adopted for water defluoridation including electrodialysis, 5 adsorption, 6 ion exchange, 7 electrocoagulation, 8 and reverse osmosis. 9,10 These well-established methods can reduce F − concentration to a tolerable level (1.5 mg L −1 as recommended by the World Health Organization (WHO)).…”
Section: Introductionmentioning
confidence: 99%
“…There is a study on nitrate and uoride removal, which was investigated in 2022, where at pH = 5.94, current density of 9.09 mA.cm − 2 and aluminum electrodes nitrate and uoride removal were 42.83% and 88.28%, respectively (Tounsi et al, 2022).…”
Section: Introductionmentioning
confidence: 99%