2016
DOI: 10.1016/j.jdent.2015.12.008
|View full text |Cite
|
Sign up to set email alerts
|

Electromagnetic interference of endodontic equipments with cardiovascular implantable electronic device

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
13
0
1

Year Published

2017
2017
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 12 publications
(14 citation statements)
references
References 20 publications
0
13
0
1
Order By: Relevance
“…A total of 445 studies were excluded, and the full-text of 15 studies were assessed for eligibility. Among these 15 articles, seven fulfilled the inclusion criteria: five in vitro [1,3,10,15,20]; and two in vivo [21,22] studies. Figure 1 summarizes the details and results of the search strategy.…”
Section: Resultsmentioning
confidence: 99%
See 3 more Smart Citations
“…A total of 445 studies were excluded, and the full-text of 15 studies were assessed for eligibility. Among these 15 articles, seven fulfilled the inclusion criteria: five in vitro [1,3,10,15,20]; and two in vivo [21,22] studies. Figure 1 summarizes the details and results of the search strategy.…”
Section: Resultsmentioning
confidence: 99%
“…Four in vitro studies [1,3,15,20] reported that electronic apex locators do not interfere with cardiovascular implantable electronic devices and can be used safely. One in vitro study [10], however, reported that electronic apex locators caused electromagnetic interference without altering cardiovascular implantable electronic devices function and suggested that electronic devices should be kept to use at minimum distances. One in vivo study [21] reported that electronic apex locators did not interfere with the functioning of cardiac devices.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…All except the CO 2 and ruby lasers were found to generate electromagnetic field strengths below the permissible limits for CIEDs (17). A similar Brazilian in vitro study in 2015 assessed the EMI between the CIEDs and the endodontic laser devices and reported no interference caused by the endodontic TwinFlex laser (wavelength range 660-808 nm) device (18). Another study evaluating the in vitro EMI between the CIEDs and ophthalmic laser systems (wavelength range 193-1,064 nm) concluded that the CIEDs were not affected by the EMI generated by the ophthalmic laser systems (19).…”
Section: Light Amplification By Stimulated Emission Of Radiation (Laser)mentioning
confidence: 92%