2004
DOI: 10.1088/0031-9155/49/20/003
|View full text |Cite
|
Sign up to set email alerts
|

Electron paramagnetic resonance (EPR) dosimetry using lithium formate in radiotherapy: comparison with thermoluminescence (TL) dosimetry using lithium fluoride rods

Abstract: Solid-state radiation dosimetry by electron paramagnetic resonance (EPR) spectroscopy and thermoluminescence (TL) was utilized for the determination of absorbed doses in the range of 0.5-2.5 Gy. The dosimeter materials used were lithium formate and lithium fluoride (TLD-100 rods) for EPR dosimetry and TL dosimetry, respectively. 60Co gamma-rays and 4, 6, 10 and 15 MV x-rays were employed. The main objectives were to compare the variation in dosimeter reading of the respective dosimetry systems and to determine… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
25
0
2

Year Published

2007
2007
2019
2019

Publication Types

Select...
4
3
1

Relationship

0
8

Authors

Journals

citations
Cited by 36 publications
(27 citation statements)
references
References 22 publications
0
25
0
2
Order By: Relevance
“…Dosimetry was performed by use of solid-state electron paramagnetic resonance (EPR) spectroscopy. Parallel to irradiation of cells, tablets of polycrystalline lithium formate monohydrate (HCO 2 Li H 2 O) were also irradiated (Vestad et al 2003(Vestad et al , 2004. The tablets were produced using a 5.0 mm diameter Weber (Paul-Otto Weber, Remshalden, Germany, PW10, Nr W 15093-0796) pellet press (10 kN for 1 min).…”
Section: Irradiationmentioning
confidence: 99%
“…Dosimetry was performed by use of solid-state electron paramagnetic resonance (EPR) spectroscopy. Parallel to irradiation of cells, tablets of polycrystalline lithium formate monohydrate (HCO 2 Li H 2 O) were also irradiated (Vestad et al 2003(Vestad et al , 2004. The tablets were produced using a 5.0 mm diameter Weber (Paul-Otto Weber, Remshalden, Germany, PW10, Nr W 15093-0796) pellet press (10 kN for 1 min).…”
Section: Irradiationmentioning
confidence: 99%
“…Lithium formate has shown to be a robust dosimeter material with high stability of the radiation induced free radicals, a linear dose response over a wide range (0.5 -1000 Gy) and up to seven times higher sensitivity than the most common EPR dosimetry material alanine (Vestad et al, 2003;Vestad et al, 2004;Lund et al, 2002). The dosimetry system was developed during a dissertation work studying sensitive materials for EPR dosimetry (Gustafsson, 2008).…”
Section: Lithium Formate Monohydratementioning
confidence: 99%
“…Gy (Malinen et al, 2007), 5 mm diameter x 2.5 mm height and doses 3 -6 Gy (Waldeland et al, 2010b), 5 mm diameter x 3.5 ± 0.2 mm height and doses 0.5 -2.5 Gy (Vestad et al, 2004a), especially applied with low doses.…”
Section: Resultsmentioning
confidence: 99%
“…Lithium formate pellets were already reported in literature, standing out because of the non-necessity of binders (Vestad et al, 2004a). A test with pellets of dimensions 9.7 mm height and 4 mm diameter was carried out.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation