Electron spectrometry with Silicon drift detectors: a GEANT4 based method for detector response reconstruction

Abstract: Precision electron spectrometry in the keV range has always been considered a challenging task. The reconstruction of the original electron energy from the detected signal is not trivial because multiple effects modify the kinetic energy of the electron along its path. If not correctly accounted for, these effects can spoil and bias the reconstructed energy with a dramatic reduction of accuracy and precision. In this paper we address one of the most critical aspects of electron spectrometry: the generally unkn… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
9
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 14 publications
(9 citation statements)
references
References 12 publications
0
9
0
Order By: Relevance
“…Here, we present first characterization measurements of a 7 −pixel prototype SDD with monoenergetic electrons at room temperature [142,144,145]. A scanning electron microscope was used as a calibration source.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…Here, we present first characterization measurements of a 7 −pixel prototype SDD with monoenergetic electrons at room temperature [142,144,145]. A scanning electron microscope was used as a calibration source.…”
Section: Discussionmentioning
confidence: 99%
“…More details on the electron characterization measurements can be found in Ref. [142,144,145], including an estimation of the entrance-window thickness, as well as the impact of the detector response on the sterile neutrino sensitivity.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…To test the general performance of the novel detector system, several measurements were performed with 1-, 7-and 47-pixel prototype detectors in dedicated setups [144][145][146][147]. In particular, we investigated the energy resolution, linearity, and electronic noise of the system.…”
Section: Detector Characterizationmentioning
confidence: 99%
“…The same issues affect also the most advanced tool for electron spectroscopy, i.e. Silicon Drift Detector [11], even if recent results demonstrate the possibility to include these effects in the Monte Carlo simulations [12]. On the other hand, cryogenic macro-calorimeters have recently been used for the first time to study the spectral shape of the two-neutrino double-beta decay [13,14,15],demonstrating their potential for this application.…”
Section: Introductionmentioning
confidence: 99%