2014
DOI: 10.1007/s10439-014-1129-y
|View full text |Cite
|
Sign up to set email alerts
|

Emerging Trends in Heart Valve Engineering: Part III. Novel Technologies for Mitral Valve Repair and Replacement

Abstract: Abstract-In this portion of an extensive review of heart valve engineering, we focus on the current and emerging technologies and techniques to repair or replace the mitral valve. We begin with a discussion of the currently available mechanical and bioprosthetic mitral valves followed by the rationale and limitations of current surgical mitral annuloplasty methods; a discussion of the technique of neo-chordae fabrication and implantation; a review the procedures and clinical results for catheter-based mitral l… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
29
0

Year Published

2015
2015
2018
2018

Publication Types

Select...
8
1

Relationship

1
8

Authors

Journals

citations
Cited by 38 publications
(29 citation statements)
references
References 59 publications
0
29
0
Order By: Relevance
“…(52) Specific anatomic considerations are fundamental for the successful implementation of such devices, yet the principle anatomic features can vary significantly between prospective patients. The mitral annular area, anterior mitral leaflet length, aortic-mitral angle, LVOT area, and specific sub-valvular and annular calcium depositions are just some of the considerations.…”
Section: Cardiovascular Applicationsmentioning
confidence: 99%
“…(52) Specific anatomic considerations are fundamental for the successful implementation of such devices, yet the principle anatomic features can vary significantly between prospective patients. The mitral annular area, anterior mitral leaflet length, aortic-mitral angle, LVOT area, and specific sub-valvular and annular calcium depositions are just some of the considerations.…”
Section: Cardiovascular Applicationsmentioning
confidence: 99%
“…1) of Sorin Biomedica Cardio (Italy). Transplantation of such a valve with a diameter d  25 mm is performed mainly in the left ventricle of the heart with aortic or mitral valve prosthetics [13,14]. In research, a mechanical bileaflet valve was placed in the mitral valve position between the left atrium and the left ventricular chamber.…”
Section: Experimental Setup and Research Techniquementioning
confidence: 99%
“…[84] For a summary of recent progress in engineering approaches to valve disease, we refer the reader to a recent three-part review. [8587]…”
Section: Valves and Devicesmentioning
confidence: 99%