2011
DOI: 10.1002/dac.1360
|View full text |Cite
|
Sign up to set email alerts
|

Empirical analysis of the reliability of low‐rate wireless u‐healthcare monitoring applications

Abstract: In this paper, we demonstrate an empirical analysis of the reliability of low-rate wireless u-healthcare monitoring applications. We have considered the performance analysis of the IEEE 802.15.4 low-rate wireless technologies for u-healthcare applications. For empirical measurement, we considered three scenarios in which the reliability features of the low-rate wireless u-healthcare monitoring applications have been measured: (i) distance between sensor nodes and base station; (ii) deployment of the number of … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
8
0

Year Published

2013
2013
2016
2016

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 13 publications
(8 citation statements)
references
References 8 publications
0
8
0
Order By: Relevance
“…The combination of BSNs and 5G has the potential to revolutionize many application fields including medical applications, context‐aware computing, and sports training. We list two interesting examples in the succeeding texts.Example (Health care and emergency response system ). BSNs enable wireless monitoring and tracking of patients.…”
Section: Background and Related Workmentioning
confidence: 99%
“…The combination of BSNs and 5G has the potential to revolutionize many application fields including medical applications, context‐aware computing, and sports training. We list two interesting examples in the succeeding texts.Example (Health care and emergency response system ). BSNs enable wireless monitoring and tracking of patients.…”
Section: Background and Related Workmentioning
confidence: 99%
“…The features of low power consumption and data rate have made IEEE 802.15.4 being an active candidate for these applications. In [29], the performance of IEEE 802.15.4 in u-healthcare applications is analyzed through experiments. Additionally, simulation has been widely used in the performance evaluation of other wireless protocols.…”
Section: Related Workmentioning
confidence: 99%
“…With this security threat, there have been secondary damages, including life threat on users, the illegal collection of information and transactions, and insurance fraud from the manipulation of biological information [6][7][8]. There has been an actively exerted effort to solve security issues about important information such as personal or medical information.…”
Section: Introductionmentioning