2016 International Symposium on Electromagnetic Compatibility - EMC EUROPE 2016
DOI: 10.1109/emceurope.2016.7739282
|View full text |Cite
|
Sign up to set email alerts
|

EN50561-3: Not an EMC standard, but an unacceptable licence to cause interference

Abstract: The EN 50561-3, a power line communication standard, has been published. It allows very high interference levels, and is neglecting the allocation of the very high frequency band 30 MHz -87.5 MHz, which is mainly assigned to military communication. It is shown that these communication systems are severely degraded, in our experiment a reduction of performance of 44 dB was measured. The military personal who are, especially after recent terrorist attacks and the following lockdowns, active in our cities to safe… Show more