2001
DOI: 10.1097/00129492-200111000-00027
|View full text |Cite
|
Sign up to set email alerts
|

Endoscope-guided Round Window Fistula Repair

Abstract: A transmyringeal endoscopic procedure for round window fistula repair is feasible and combines the best features of minimally invasive surgery and aural endoscopy.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
19
0
4

Year Published

2010
2010
2023
2023

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 24 publications
(23 citation statements)
references
References 11 publications
0
19
0
4
Order By: Relevance
“…In narrow and curved external auditory canals, this may represent an even greater limitation, requiring other access pathways to the middle ear like posterior auricular approach. 3,4 Even with extended access to the middle ear, one of the important steps in performing stapes surgery under the microscope is to partially remove the bony wall of the posterosuperior part of the external auditory canal. This important step in this surgery enables a better exposure of the incudostapedial joint, oval window, pyramidal eminence and other important middle ear structures.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…In narrow and curved external auditory canals, this may represent an even greater limitation, requiring other access pathways to the middle ear like posterior auricular approach. 3,4 Even with extended access to the middle ear, one of the important steps in performing stapes surgery under the microscope is to partially remove the bony wall of the posterosuperior part of the external auditory canal. This important step in this surgery enables a better exposure of the incudostapedial joint, oval window, pyramidal eminence and other important middle ear structures.…”
Section: Introductionmentioning
confidence: 99%
“…[1][2][3][4][5] Sinonasal scopes with 4mm diameter and 18 cm length, with wide-angle lens and different angles, allow for an amplified image which can be quickly modified by advancing or pulling the instrument back.…”
Section: Introductionmentioning
confidence: 99%
“…However, such limitation inherent to the equipment limits visual field when we make exclusively transcanal access in the narrowest segment of the external ear canal. In winding canals, this may represent an even greater limitation, requiring other access pathways to the middle ear, behind the ear or modified transcanal approaches 3,4 . Even with extended access to the middle ear, one of the important steps in performing stapes surgeries under the microscope is to partially remove the bone wall of the most medial segment of the external acoustic meatus.…”
Section: Introductionmentioning
confidence: 99%
“…Although endoscopes were introduced in ear surgeries over 15 years ago, their role have been rather limited in the treatment of middle ear inflammatory disorders and otosclerosis [1][2][3][4][5] . There are many reasons for this, such as the belief of a limited and marginal role endoscopes play in middle ear surgery, instrument limitation, and a potentially long learning curve in order to get used to single-handed work and the lack of a stereoscopic view 2,3 .…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation