2015
DOI: 10.1055/s-0034-1392509
|View full text |Cite
|
Sign up to set email alerts
|

Endoscopic Submucosal Dissection for Early Gastric Cancer using the Clutch Cutter: a large single-center experience

Abstract: Background and study aims: The Clutch Cutter (CC) was developed to reduce the risk of complications related to endoscopic submucosal dissection (ESD) using knives. The CC is able to grasp and coagulate and/or incise the targeted tissue using electrosurgical current, like a biopsy technique. The aim of this study was to evaluate the efficacy and safety of ESD using the CC (ESD-CC) for early gastric cancer (EGC). Patients and methods: From June 2007 to March 2014, 325 consecutive patients with a diagnosis of EG… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
32
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
6
3

Relationship

3
6

Authors

Journals

citations
Cited by 22 publications
(32 citation statements)
references
References 30 publications
0
32
0
Order By: Relevance
“…There was no uncontrollable intraoperative bleeding in our previous reports on ESD[ 11 - 17 ]. We were able to quickly and easily stop intraoperative bleeding using the CC[ 15 ] without changing the device for the entire gastrointestinal tract. In the present study, we did not perform any unexpected incisions.…”
Section: Discussionmentioning
confidence: 99%
“…There was no uncontrollable intraoperative bleeding in our previous reports on ESD[ 11 - 17 ]. We were able to quickly and easily stop intraoperative bleeding using the CC[ 15 ] without changing the device for the entire gastrointestinal tract. In the present study, we did not perform any unexpected incisions.…”
Section: Discussionmentioning
confidence: 99%
“…VIO 300D (ERBE Elektromedizin, GmbH, Tübingen, Germany) was used as the electrical power source. The ESD procedure was described in detail in previous reports[7,12,13]. In brief, marking dots were made 2 mm outside the lesion.…”
Section: Methodsmentioning
confidence: 99%
“…ESD with Clutch Cutter (ESD-C) may then become an option of endo-knife for ESD. Favorable outcomes of ESD-C have been reported, including in a large single-center study with single arm trial[7-9]. However, few reports exist showing the comparison between scissors-type and non-scissors-type knives in the technical outcomes of ESD, which have been limited to non-experts in inclusion criteria[10,11].…”
Section: Introductionmentioning
confidence: 99%
“…The width and length of the jaws is 0.4-mm and 5-mm respectively[5-9]. The jaws can be rotated 360 degrees and the outer edges are insulated to minimize the electrical risk.…”
Section: Methodsmentioning
confidence: 99%