2016
DOI: 10.1007/s00464-016-4827-8
|View full text |Cite
|
Sign up to set email alerts
|

Endoscopic submucosal dissection with the Nestis® jet injector system with a bifunctional catheter: first prospective clinical trial (NCT: 2012-A00272-41)

Abstract: ESD with Enki-2 water jet system is effective and safe for superficial neoplastic digestive lesions.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
3
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
3

Relationship

2
1

Authors

Journals

citations
Cited by 3 publications
(3 citation statements)
references
References 14 publications
(23 reference statements)
0
3
0
Order By: Relevance
“…The result is better visualization of the plane and less fluid in the digestive cavity, which can interfere with the procedure. High-pressure strategies have shown their increased safety and effectiveness, particularly when combined with injection of macromolecule viscous solutions [70, 71]. Insulated tipThese knives are best used when pulling back (far to near side) or laterally.…”
Section: Endoscopic Submucosal Dissectionmentioning
confidence: 99%
See 1 more Smart Citation
“…The result is better visualization of the plane and less fluid in the digestive cavity, which can interfere with the procedure. High-pressure strategies have shown their increased safety and effectiveness, particularly when combined with injection of macromolecule viscous solutions [70, 71]. Insulated tipThese knives are best used when pulling back (far to near side) or laterally.…”
Section: Endoscopic Submucosal Dissectionmentioning
confidence: 99%
“…The result is better visualization of the plane and less fluid in the digestive cavity, which can interfere with the procedure. High-pressure strategies have shown their increased safety and effectiveness, particularly when combined with injection of macromolecule viscous solutions[70,71].-Insulated tip• These knives are best used when pulling back (far to near side) or laterally. During ESD, IT knives generally anchor in the margin of the specimen,…”
mentioning
confidence: 99%
“…To obtain the first lift with the needle, it is necessary to prick deeply and to inject very gently by gradually withdrawing the needle until a bluish fish bladder bubble appears, reflecting a submucosal injection. Another option is possible, without a needle, with high-pressure knife injectors, such as the Hybrid Knife (Erbe, Tuebingen, Germany) or the Nestis Enki II (Nestis, Lyon, France), which allow the pressurized water jet to pass through the mucosa and fill the submucosa directly 8 9 .…”
Section: Submucosal Injectionmentioning
confidence: 99%