Engineering a Hollow Carbon Sphere‐Based Triphase Microenvironment for Enhanced Enzymatic Reaction Kinetics and Bioassay Performance

Abstract: Electrochemical bioassays based on oxidase reactions are frequently used in biological sciences and medical industries. However, the enzymatic reaction kinetics are severely restricted by the poor solubility and slow diffusion rate of oxygen in conventional solid‒liquid diphase reaction systems, which inevitably compromises the detection accuracy, linearity, and reliability of the oxidase‐based bioassay. Herein, an effective solid‒liquid‒air triphase bioassay system is provided that uses hydrophobic hollow car… Show more