Enhanced temporal resolution for the microdialysis monitoring of catecholamines and excitatory amino acids using capillary electrophoresis with laser-induced fluorescence detection Analytical developments and in vitro validations

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

2
50
0

Year Published

1999
1999
2008
2008

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 74 publications
(52 citation statements)
references
References 34 publications
2
50
0
Order By: Relevance
“…Microdialysis sampling started 120 min after probe placement into the PFC. The outlet of the probe was connected to an online derivatization system as described previously (Bert et al, 1996), allowing direct analysis of dialysate samples collected every 15 min.…”
Section: Effect Of Ssr504734 On Extracellular Levels Of Glycine Measumentioning
confidence: 99%
See 1 more Smart Citation
“…Microdialysis sampling started 120 min after probe placement into the PFC. The outlet of the probe was connected to an online derivatization system as described previously (Bert et al, 1996), allowing direct analysis of dialysate samples collected every 15 min.…”
Section: Effect Of Ssr504734 On Extracellular Levels Of Glycine Measumentioning
confidence: 99%
“…Before analysis, the samples were derivatized using naphtalene-2,3-dicarboxaldehyde and sodium cyanide, as described previously (Bert et al, 1996). CE experiments were performed on a P/ACE MDQ capillary electrophoresis system (Beckman Coulter, Villepinte, France) coupled to an external Zetalif fluorescence detector (Picometrics SA, Toulouse, France).…”
Section: Effect Of Ssr504734 On Extracellular Levels Of Glycine Measumentioning
confidence: 99%
“…When techniques such as HPLC are used, the temporal resolution is often 10-30 min; 7 however, coupling microdialysis to nanoscale analytical techniques such as capillary electrophoresis (CE), microbore liquid chromatography (LC), and electrochemical sensors have shortened sampling times to seconds. 4,[8][9][10][11][12][13][14][15][16][17][18] When using high sensitivity analytical methods, other factors can begin to limit temporal resolution achievable with microdialysis sampling. One inherent limitation is broadening of sample zones due to Taylor dispersion as they are transferred from sampling probe to analytical system.…”
Section: Introductionmentioning
confidence: 99%
“…In microdialysates, the CA determination by CZE-LIFD has been performed in low concentration, small volume samples derivatized with NAD to give highly fluorescent compounds. Robert et al [136] and Bert et al [137] have accomplished very reliable and sensitive determinations of CA. NE detection limit was 5 Â 10 À9 M in rat medial frontal cortex microdialysates [136].…”
Section: Ce-lifd Coupled To Microdialysis Studies Neuroactive Substamentioning
confidence: 99%
“…The performance of the method is demonstrated in vitro by monitoring rapid fluctuations in the CA concentration in the external microdialysis medium. It was possible to reach the separation of subnanomolar concentrations of DA and NA in less than 2-min run and with high efficiency [137]. The derivatization with NDA has been performed on line [55].…”
Section: Ce-lifd Coupled To Microdialysis Studies Neuroactive Substamentioning
confidence: 99%