2021
DOI: 10.1016/j.est.2021.103116
|View full text |Cite
|
Sign up to set email alerts
|

Enhanced thermal performance of finned latent heat thermal energy storage system: fin parameters optimization

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
7
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 35 publications
(8 citation statements)
references
References 46 publications
1
7
0
Order By: Relevance
“…These numbers were chosen so that we could solve the numerical issue with a convergence criterion of 10 −5 in the shortest amount of time possible. The time independence test yields the same findings for various time steps when utilizing an adaptive time‐stepping strategy, as has been demonstrated in earlier work 63 . Figure 6 shows grid‐independent investigations of the model.…”
Section: Numerical Procedures and Validationsupporting
confidence: 77%
See 1 more Smart Citation
“…These numbers were chosen so that we could solve the numerical issue with a convergence criterion of 10 −5 in the shortest amount of time possible. The time independence test yields the same findings for various time steps when utilizing an adaptive time‐stepping strategy, as has been demonstrated in earlier work 63 . Figure 6 shows grid‐independent investigations of the model.…”
Section: Numerical Procedures and Validationsupporting
confidence: 77%
“…The time independence test yields the same findings for various time steps when utilizing an adaptive time-stepping strategy, as has been demonstrated in earlier work. 63 Figure 6 shows grid-independent investigations of the model.…”
Section: Grid Independent Investigationsmentioning
confidence: 99%
“…Based on the aforementioned literary survey, there are few studies concerning with the melting enhancement of PCM in wavy finned tubes latent heat thermal energy storage are presented. One of these studies is that of Elmaazouzi et al 44 where the enhancement of the thermal performance of finned latent heat thermal energy storage system was examining. Therefore, the main objective of this investigation is to examine the impacts of the non-regular outer boundaries together with heated fins attached with a rotating cylinder on the heat transfer rate, melting rate and temperature distributions.…”
Section: Abbreviationsmentioning
confidence: 99%
“…The difference in spatial sampling results in a difference in papers which report the internal energy. In numerical studies reporting internal energy as a function of time is commonly done although most studies report latent stored internal energy (e.g., [71,99,104,130]) or total liquid fraction (e.g., [65, 66, 68, 70, 71, 75, 77, 93, 99, 102, 104, 106, 109, 111, 113, 115, 120-122, 124-128, 130-132, 134, 136]) instead of total stored energy (e.g., [75,111,115,134,137,138]). In experimental studies, the total liquid fraction is sometimes reported (e.g., [67,87,101]) however local temperature measurements are far more commonly reported (e.g., [63,64,69,72,76,83,[87][88][89][90][91][92][93][94][95][96][97][98][99][100][101][102][103][105][106][107][108][109][110][111]…”
Section: State Indicatorsmentioning
confidence: 99%