2013
DOI: 10.1016/j.bspc.2012.09.002
|View full text |Cite
|
Sign up to set email alerts
|

Enhanced ultrasound strain imaging using chirp-coded pulse excitation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

2
13
0

Year Published

2013
2013
2018
2018

Publication Types

Select...
5
2

Relationship

2
5

Authors

Journals

citations
Cited by 15 publications
(15 citation statements)
references
References 36 publications
2
13
0
Order By: Relevance
“…For one subarray one covariance matrix is calculated. If we have P subarrays of length L, the formula for the averaged covariance matrix will become [5]: (4) where P = M -L + land g p is the ih transducer subarray: (5) with p = 0, I, ... , p -I. The averaging over the all P subarrays is expressed as:…”
Section: Adaptive Beamformingmentioning
confidence: 99%
See 1 more Smart Citation
“…For one subarray one covariance matrix is calculated. If we have P subarrays of length L, the formula for the averaged covariance matrix will become [5]: (4) where P = M -L + land g p is the ih transducer subarray: (5) with p = 0, I, ... , p -I. The averaging over the all P subarrays is expressed as:…”
Section: Adaptive Beamformingmentioning
confidence: 99%
“…The use of Golay codes and Hadamard matrices were discussed in terms of increasing the frame rate of image formation. Reference [4] is a recent in-deep study of the chirp excitation for ultrasound strain imaging. The chirp excitation seems to give the best results for improving the SNR of ultrasound images.…”
Section: Introductionmentioning
confidence: 99%
“…One of major quality metrics of strain images is elastographic signal-to-noise ratio (SNRe) affected by many factors, such as echo signal-tonoise ratio (eSNR), applied strain, attenuation, etc. Many methods [2][3][4][5][6] were proposed to improve the quality of ulrasound strain imaging.…”
Section: Introductionmentioning
confidence: 99%
“…Jie Liu et al [4] first applied coded excitation to ultrasonic strain imaging. Reference [5] studied the effects of various factors on chirp-coded strain imaging. In this paper, we applied Golay codes to elasticity imaging to improve its quality.…”
Section: Introductionmentioning
confidence: 99%
“…Conventionally in the research literature, while characterizing the performance of the strain images for lesion detectability only CNR e is used as a quality metric and strain images with higher values are regarded as optimal strain image [6], [7]. Although, the strain contrast generated during deformation of the soft tissue results from complex interaction between the elastic profile of the tissue, tumour's shape, size, location, and boundary conditions [8].…”
Section: Introductionmentioning
confidence: 99%