2011
DOI: 10.1109/tasc.2010.2100799
|View full text |Cite
|
Sign up to set email alerts
|

ENSYSTROB—Resistive Fault Current Limiter Based on Coated Conductors for Medium Voltage Application

Abstract: A new German government funded project for a resistive fault current limiter has started in September 2009 (ENSYS-TROB) and is presented. The consortium includes partners from industry, research centers and utilities. It aims the construction of a 3-phase medium voltage current limiter (12 kV, 800 A) for the protection of the domestic supply in a power plant. A special feature of this application is the presence of large in-rush currents (4100 Ap for 50 ms, 1800 A for 15 s). The superconducting components are … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
13
0

Year Published

2011
2011
2021
2021

Publication Types

Select...
7
1
1

Relationship

0
9

Authors

Journals

citations
Cited by 50 publications
(13 citation statements)
references
References 13 publications
0
13
0
Order By: Relevance
“…Recently, a number of practical superconducting fault current limiter (SFCL) devices have been successfully developed and demonstrated by in-grid tests. The current motivation on the applied superconductivity technology to build SFCL devices has been moving from the 10-kV distribution level [26,27] to the 100-kV transmission level [27,28].So far, fault current limiters have been comprehensively studied and applied in AC power grids to limit fault currents and to improve the dynamic performance of the system. However, the application of FCLs in VSC-HVDC systems has not been fully investigated [29].…”
mentioning
confidence: 99%
“…Recently, a number of practical superconducting fault current limiter (SFCL) devices have been successfully developed and demonstrated by in-grid tests. The current motivation on the applied superconductivity technology to build SFCL devices has been moving from the 10-kV distribution level [26,27] to the 100-kV transmission level [27,28].So far, fault current limiters have been comprehensively studied and applied in AC power grids to limit fault currents and to improve the dynamic performance of the system. However, the application of FCLs in VSC-HVDC systems has not been fully investigated [29].…”
mentioning
confidence: 99%
“…1(a)], similar to the ENSYSTROB components described in [6], consisting of two anti-parallel shunted HTS coils with four paths of twin 2G tapes [SF12100, Fig. 2(a)].…”
Section: Studied Sfcls Devicesmentioning
confidence: 99%
“…Different types of SFCLs have been developed until now [10][11][12][13]. Many models for SFCL have been designed as resistor-type, reactor-type, and transformer-type etc.…”
Section: Basics Of Sfclmentioning
confidence: 99%