2016
DOI: 10.2527/jas.2016-0646
|View full text |Cite
|
Sign up to set email alerts
|

Enteric methane and carbon dioxide emissions measured using respiration chambers, the sulfur hexafluoride tracer technique, and a GreenFeed head-chamber system from beef heifers fed alfalfa silage at three allowances and four feeding frequencies1–3

Abstract: The objective of this study was to determine methane (CH) and carbon dioxide (CO) emissions from 8 beef heifers (approximately 20 mo of age and 382 ± 24.3 kg BW) measured by respiration chambers and the sulfur hexafluoride (SF) tracer technique and a mobile head-chamber, spot-sampling system (GreenFeed; C-Lock Inc., Rapid City, SD) when fed alfalfa silage at 3 feeding levels and 4 feeding frequencies. Feeding frequency may affect CH yield (g/kg DMI), and measurement systems (such as GreenFeed or SF) are needed… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
26
1
1

Year Published

2019
2019
2024
2024

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 30 publications
(28 citation statements)
references
References 28 publications
0
26
1
1
Order By: Relevance
“…The GreenFeed system has been compared to RC and has shown mixed results for agreement, with poor concordance (CCC = 0.1) in dairy cattle but high concordance in beef cattle (CCC = 0.84) . In most studies, the accuracy was not significantly different from that of the RC, but the GreenFeed had higher variation and was less precise Jonker et al, 2016;Rischewski et al, 2017). Typical sources of imprecision for the GreenFeed include the duration and number of visits.…”
Section: The Greenfeed Systemmentioning
confidence: 89%
See 3 more Smart Citations
“…The GreenFeed system has been compared to RC and has shown mixed results for agreement, with poor concordance (CCC = 0.1) in dairy cattle but high concordance in beef cattle (CCC = 0.84) . In most studies, the accuracy was not significantly different from that of the RC, but the GreenFeed had higher variation and was less precise Jonker et al, 2016;Rischewski et al, 2017). Typical sources of imprecision for the GreenFeed include the duration and number of visits.…”
Section: The Greenfeed Systemmentioning
confidence: 89%
“…Visitation to the unit is voluntary and requires training and adaption to the unit. Daily CH 4 emissions (g/d) are estimated using volumetric airflow rate adjusted to standard temperature and pressure in a manner analogous to respiration chambers Jonker et al, 2016):…”
Section: The Greenfeed Systemmentioning
confidence: 99%
See 2 more Smart Citations
“…As câmaras respirométricas foram pioneiras e de grande importância para estudos com emissão de gases, e também exigências energéticas dos animais, gerando as primeiras informações para a elaboração das tabelas do NRC (NRC, 2001 as vantagens e desvantagens entre eles (BHATTA et al, 2007;DOREAU et al, 2018;DORICH et al, 2015;HAMMOND et al, 2015;HRISTOV et al, 2016;JONKER et al, 2016;MCGINN et al, 2006;OSS et al, 2016;PINARES-PATIÑO;CLARK, 2008;STORM et al, 2012;TROY et al, 2016).…”
Section: Revisão De Literaturaunclassified