Abstract:Environmental fatigue crack propagation of CF8M and CF8A steels used in the domestic nuclear power plants (NPPs) were investigated on the simulated pressurized water reactor (PWR) condition (temperature: 316°C, pressure: 15MPa). The test equipment for environmental fatigue (high temperature-high pressure loop, autoclave, load frame, and measurement system) was designed. As-received and 60-year aged specimens were used in the test. To compare with
environmental fatigue test, another test in the air condition wa… Show more
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.