Enzymatic Determination of Serum Urea on the Surface of Silicone-Rubber Pads

Abstract: An enzymatic, fluorometric method is described for determination of serum urea on silicone-rubber pads. In this method, the reagents are lyophilized on the surface of the pads, NADH on one side and a mixture of urease, glutamate dehydrogenase, and α-ketoglutarate on the other. The rate of disappearance of NADH fluorescence at 460 nm (excitation wavelength, 340 nm) is monitored and related to serum urea concentration. The calibration curve is linear to 250 mg of urea per liter. The method affords a rapid, simpl… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
6
0

Year Published

1976
1976
1994
1994

Publication Types

Select...
5
2
1

Relationship

0
8

Authors

Journals

citations
Cited by 18 publications
(6 citation statements)
references
References 0 publications
0
6
0
Order By: Relevance
“…In particular, it is readily possible to prepare several hundred active units of enzyme immobilized in a small (1 mL) column, thereby permitting equilibrium assays and circumventing many of the limitations of kinetic assays with soluble enzymes. Immobilized enzymes have been used in flow-through reactors of several configurations including: fixed-bed (18) and open tubular reactors (19), as well as on electrodes (20) and reagent pads (21).…”
mentioning
confidence: 99%
“…In particular, it is readily possible to prepare several hundred active units of enzyme immobilized in a small (1 mL) column, thereby permitting equilibrium assays and circumventing many of the limitations of kinetic assays with soluble enzymes. Immobilized enzymes have been used in flow-through reactors of several configurations including: fixed-bed (18) and open tubular reactors (19), as well as on electrodes (20) and reagent pads (21).…”
mentioning
confidence: 99%
“…Therefore, this procedure can be a very useful method for monitoring of nitrate in contaminated drinking water, as well as in food and other fields. The main disadvantages generally associated with most fluorescence methods, i.e., (1) errors from fluorescing contaminants such as aromatic organic compounds in the water sample and (2) sample matrix effects generally caused by spectral and nonspectral interferences associated with the matrix, are not as important in solid-surface methods such as the one described herein. Any strongly fluorescing com-pounds present, which absorb or emit at the same wavelengths as NADH, would interfere.…”
Section: Resultsmentioning
confidence: 99%
“…Chlorella vulgaris was a kind gift from L. P. Solomonson, Department of Biochemistry, College of Medicine, University of South Florida. 1 Present address, Department of Chemical Engineering and Nuclear Engineering, Iowa State University, Ames, Iowa 50011.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…After reconstitution the analyte solution is placed on the pad and allowed to diffuse into the gel. An interesting example is found in the analysis of serum urea in which urease, glutamate dehydrogenase, and NADH are entrapped in the pad (21). Upon addition of serum, the hydrolysis of urea is coupled to the removal of NADH by the reactions: urease Urea + H+ + 2HaO ^=±; 2NH4+ + hco3-(D a-ketoglutarate + NH4+ glutamate + NADH NAD+ dehydrogenase + glutamate + H20 (2) Quantitation is accomplished by monitoring the change in fluorescence as a function of time.…”
Section: Analytical Applicationsmentioning
confidence: 99%