2019
DOI: 10.1016/j.jelechem.2018.12.027
|View full text |Cite
|
Sign up to set email alerts
|

Enzyme immobilization on ZIF-67/MWCNT composite engenders high sensitivity electrochemical sensing

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
26
0
1

Year Published

2019
2019
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 74 publications
(28 citation statements)
references
References 45 publications
1
26
0
1
Order By: Relevance
“…[28] As well as for colorimetric sensing,r obust enzyme@MOFs biocomposites were also proposed to fabricate ultra-stable modified-electrode for electrochemical biosensing. [33] Furthermore,detecting disease biomarkers is critical for clinical diagnosis and the subsequent effective therapeutics.Aportable and robust enzyme@-MOFs-based on-paper biosensor enabling point-of-care diagnosis is undergoing in our group.T he designed new paperbased biosensor enables to analyze on-site different important disease-related biomolecules through modulating the enzyme cascades,c ombining with ac ustom-designed smartphone for signal readout.…”
Section: Angewandte Chemiementioning
confidence: 99%
“…[28] As well as for colorimetric sensing,r obust enzyme@MOFs biocomposites were also proposed to fabricate ultra-stable modified-electrode for electrochemical biosensing. [33] Furthermore,detecting disease biomarkers is critical for clinical diagnosis and the subsequent effective therapeutics.Aportable and robust enzyme@-MOFs-based on-paper biosensor enabling point-of-care diagnosis is undergoing in our group.T he designed new paperbased biosensor enables to analyze on-site different important disease-related biomolecules through modulating the enzyme cascades,c ombining with ac ustom-designed smartphone for signal readout.…”
Section: Angewandte Chemiementioning
confidence: 99%
“…Unfortunately, the absorption efficacy was low because of the hydrophobic property of the electrospun PCL fiber mat. A previous study indicated that the absorption efficiency of the enzyme could be remarkably enhanced with an increase in hydrophilicity [ 26 , 27 ]. Therefore, hydrophilic modification of the PCL fiber mat might be a proper way to improve the detection performance of the designed detection card.…”
Section: Resultsmentioning
confidence: 99%
“…[28] Abgesehen von kolorimetrischen Sensoren wurde vorgeschlagen, Enzym@MOF-Biokomposite auch als ultrastabile modifizierte Elektroden füre lektrochemische Biosensoren zu verwenden. [33] Ferner sind Detektoren fürK rankheitsbiomarker außerordentlich wichtig fürd ie medizinische Diagnostik und anschließende Therapie.W eitere Untersuchungen an tragbaren, robusten Enzym@MOF-Biosensor-Teststreifen fürd ie patientennahe Diagnostik werden gegenwärtig in unserer Arbeitsgruppe durchgeführt. Die entwickelten Biosensorteststreifen ermçglichen eine Vor-Ort-Analyse verschiedener wichtiger,k rankheitsrelevanter Biomoleküle durch die Modulierung der Enzymkaskaden, wobei ein speziell angepasstes Smartphone zum Auslesen des Signals verwendet wird.…”
Section: Sensorikunclassified