Enzyme-linked immunosorbent assay for detection of measles antibody

Abstract: An enzyme-linked immunosorbent assay (ELISA) was developed for the detection of measles immunoglobulin G antibody (MEASELISA). This assay was found to be comparable to the measles hemagglutination inhibition (HAI) test. Approximately 500 sera from three centers were tested by MEASELISA and the HAI test. MEASELISA demonstrated values of greater than 99% for sensitivity, specificity, and accuracy. Values were very precise, with a mean coefficient of variation of 5.4%. MEASELISA values were shown by linear regres… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
17
0

Year Published

1987
1987
2003
2003

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 45 publications
(17 citation statements)
references
References 7 publications
0
17
0
Order By: Relevance
“…Different serological assays measure diverse subsets of MV antibodies, and it is not clear which subset reflects the cellular immune response best. Whole MV-based ELISAs detect a broad range of immunoglobulins, irrespective of their functional activities (8,15,35,50). Functional assays, such as HI and NT, are therefore considered to provide a better estimate of the immune status.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…Different serological assays measure diverse subsets of MV antibodies, and it is not clear which subset reflects the cellular immune response best. Whole MV-based ELISAs detect a broad range of immunoglobulins, irrespective of their functional activities (8,15,35,50). Functional assays, such as HI and NT, are therefore considered to provide a better estimate of the immune status.…”
Section: Discussionmentioning
confidence: 99%
“…Performance of the H-ELISA. The different performance parameters of the H-ELISA were compared with those of whole-virus-based ELISAs from this study and from the literature (8,12,34). For a valid comparison, all values were recalculated with the same algorithms by adding undefined sera to the sera negative by ELISA (7).…”
Section: Detection Of Mv-specific Iggmentioning
confidence: 99%
See 1 more Smart Citation
“…The coefficient of variation of this assay in our laboratory is 6.6%. We defined the subjects by optical density (OD) values as described by the manufacturer (Boteler et al, 1983). We classified subjects with index values ≤ 0.8 units as seronegative and classified subjects with values ≥ 1.0 units as seropositive.…”
Section: Antibody Measurementmentioning
confidence: 99%
“…Indirect EIAs. An indirect measles EIA was performed by a modification of the method described by Boteler et al (6). Briefly, measles virus-positive antigen and negative control cells were each diluted 1:40 in deionized H20 and dried onto microtiter plates overnight.…”
mentioning