2021
DOI: 10.1016/j.surfin.2021.100962
|View full text |Cite
|
Sign up to set email alerts
|

Equilibrium and kinetic studies for removal of antiviral sofosbuvir from aqueous solution by adsorption on expanded perlite: Experimental, modelling and optimization

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
14
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 20 publications
(15 citation statements)
references
References 42 publications
1
14
0
Order By: Relevance
“…These techniques are used in conjunction with thermal analysis (DTA) and thermogravimetric analysis (TGA) to follow the thermal evolution of these Xerogel phosphates, Thermogravimetric (TGA) and differential thermal analysis (DTA) (Labsys Evo1F Setaram). Morphological surface features were examined by applying Jeol JSM-IT100 InTouchScope™ Scanning Electron Microscope (SEM) connected to a microanalyzer EDS [ 12 ].…”
Section: Methodsmentioning
confidence: 99%
“…These techniques are used in conjunction with thermal analysis (DTA) and thermogravimetric analysis (TGA) to follow the thermal evolution of these Xerogel phosphates, Thermogravimetric (TGA) and differential thermal analysis (DTA) (Labsys Evo1F Setaram). Morphological surface features were examined by applying Jeol JSM-IT100 InTouchScope™ Scanning Electron Microscope (SEM) connected to a microanalyzer EDS [ 12 ].…”
Section: Methodsmentioning
confidence: 99%
“…Table 3 shows the maximum and minimum values for each component. The choice of the limits of the investigated region was determined using data from the literature (Colombo et al 2016 ; Attimarad et al 2020 ; Babas et al 2021 ). A total of 15 tests were required to optimize AVS extraction efficiency.…”
Section: Methodsmentioning
confidence: 99%
“…Several methods such as liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS) [49] , [50] , [51] , [52] , [53] , [54] , [55] , [56] , [57] , [58] , high-performance liquid chromatography (HPLC) [59] , [60] , [61] , [62] , [63] , [64] , ultra-performance liquid chromatography with positive electrospray ionization tandem spectrometry (UPLC-MS/MS) [65] and (ultraviolet) UV–Vis spectrophotometer [66] , [67] have been used to determine antiviral drugs from aqueous samples. In most cases, liquid chromatography-tandem mass spectrometry (LC-MS/MS) is used to quantify antiviral drugs from environmental waters and wastewaters due to high selectivity, accuracy, sensitivity and flexibility [68] , [69] .…”
Section: Occurrence and Determination Methods In The Aquatic Environmentmentioning
confidence: 99%